Setting procedure
(1) Rotate the SHUTTER dial to move the cursor to MEM.
EDIT.
(2) Push the SHUTTER dial to make the ADR parameter blink.
(3) Select ADR parameter "391".
(4) Push the SHUTTER dial to make the DATA parameter
blink.
(5) Rotate the SHUTTER dial to set the ID data for ADR =
"391".
(6) Push the SHUTTER dial to confirm the DATA parameter.
(7) In the same manner, select ADR parameter "392" and
"393" to set the ID data.
Fig. 1-9-17 ID Label Attachment Position
ID Label
1.10

SWITCHES ON DBCP BOARD

S401,S402 and CN401 are prepared to use for factory produc-
tion line, usually never use for adjustment after repair or main-
tenance, so please do not touch their and keeping on the fac-
tory setting .
1.10.1 Board location
DBCP board
2
ON
CAUTION
If there will be changed any setting except factory position,
it will occur any problem for FPGA (Field Programable Gate
Array) on DBCP board (IC401,301), cause of the Flash ROM
IC which is stored the program for FPGA will be damaged
or erased.
If the both small switches S402- 1and 2 set to down ward
(ON position), and push S401tact switch, then Flash ROM
will be erased. Be careful and never do it.
S402
CN801
CN401
S401
1
[Factory setting]
Do not re-setting
these switches.
1-19