YOKOGAWA TA720 User Manual page 66

Time interval analyzer communication interface
Hide thumbs Also See for TA720:
Table of Contents

Advertisement

:{HHIStogram<x>|THIStogram<x>}:SINGle:
HORizontal:SPAN
Function
Sets the span of the horizontal axis (X-axis) of
the single window.
Syntax
:{HHIStogram<x>|THIStogram<x>}:
SINGle:HORizontal:SPAN {<Time>}
:{HHIStogram<x>|THIStogram<x>}:
SINGle:HORizontal:SPAN?
<x>=1 to 2
• For hardware histogram mode
<Time>=1.5 ns, 3 ns, 7.5 ns, 15
ns, 30 ns, 60 ns, 150 ns, 300 ns,
600 ns, 1.5 µs, 3 µs, 6 µs
• For time stamp mode
<Time>=1.5 ns, 3 ns, 7.5 ns, 15 ns,
30 ns, 60 ns, 150 ns, 300 ns, 600
ns, 1.5 µs, 3 µs, 6 µs, 15 µs, 30
µs, 60 µs, 150 µs, 300 µs, 600 µs,
1.5 ms, 3 ms, 6 ms, 15 ms, 30 ms
Example
(The following is an example for the hardware
histogram mode.)
:HHISTOGRAM1:SINGLE:HORIZONTAL:
SPAN 300ns
:HHISTOGRAM1:SINGLE:HORIZONTAL:SPAN?
-> :HHISTOGRAM1:SINGLE:HORIZONTAL:
SPAN 0.3E-06
:{HHIStogram<x>|THIStogram<x>}:SINGle:
MARKer?
Function
Queries all settings related to the marker of the
single window.
Syntax
:{HHIStogram<x>|THIStogram<x>}:
SINGle:MARKer?
<x>=1 to 2
Example
(The following is an example for the hardware
histogram mode.)
:HHISTOGRAM1:SINGLE:MARKER?
-> :HHISTOGRAM1:SINGLE:MARKER:
LEFT 100.000E-09;RIGHT 200.000E-09
:{HHIStogram<x>|THIStogram<x>}:SINGle:
MARKer:{LEFT|RIGHt}
Function
Sets the marker position of the single window or
queries the current setting.
Syntax
:{HHIStogram<x>|THIStogram<x>}:
SINGle:MARKer:{LEFT|RIGHt} {<Time>}
:{HHIStogram<x>|THIStogram<x>}:
SINGle:MARKer:{LEFT|RIGHt}?
<x>=1 to 2
<Time>=Marker position (25 ps steps)
Example
(The following is an example for the hardware
histogram mode and left marker.)
:HHISTOGRAM1:SINGLE:MARKER:
LEFT 100ns
:HHISTOGRAM1:SINGLE:MARKER:LEFT?
-> :HHISTOGRAM1:SINGLE:MARKER:
LEFT 100.000E-09
IM 704510-17E
4.8 HHIStogram<x> and THIStogram<x> Group
:{HHIStogram<x>|THIStogram<x>}:SINGle:
MARKer:{LVALue|RVALue}?
Function
Sets the frequency of the left/right marker
position of the single window or queries the
current setting.
Syntax
:{HHIStogram<x>|THIStogram<x>}:
SINGle:MARKer:{LVALue|RVALue}?
[{POSitive|NEGative}]
<x>=1 to 2
Example
(The following is an example for the hardware
histogram mode.)
:HHISTGRAM1:SINGLE:MARKER:LVALE?
-> :HHSTOGRAM1:SINGLE:MARKER:
LVALE 1234
Description When measuring both pulse widths or both
edges and ":CALCulation:POLarity" is set
to "POSNeg", specify "POSitive|NEGative".
:{HHIStogram<x>|THIStogram<x>}:SINGle:
TVALue
Function
Sets the constant T value of the single window
or queries the current setting.
Syntax
:{HHIStogram<x>|THIStogram<x>}:
SINGle:TVALue {<Time>}
:{HHIStogram<x>|THIStogram<x>}:
SINGle:TVALue?
<x>=1 to 2
<Time>=1 ns to 250 ns (25 ps steps)
Example
(The following is an example for the hardware
histogram mode.)
:HHISTOGRAM1:SINGLE:TVALUE 100ns
:HHISTOGRAM1:SINGLE:TVALUE?
:{HHIStogram<x>|THIStogram<x>}:VERTical?
Function
Queries all settings related to the vertical axis
(Y-axis) of the hardware histogram.
Syntax
:{HHIStogram<x>|THIStogram<x>}:
VERTical?
<x>=1 to 2
Example
(The following is an example for the hardware
histogram mode.)
:HHISTOGRAM1:VERTICAL?
-> :HHISTOGRAM1:VERTICAL:
AXIS LINEAR;HIGH 1.0E+03