YOKOGAWA TA720 User Manual page 30

Time interval analyzer communication interface
Hide thumbs Also See for TA720:
Table of Contents

Advertisement

Command
TVARiation Group
:TVARiation<x>?
:TVARiation<x>:HORizonatal?
:TVARiation<x>:HORizonatal:MINimum
:TVARiation<x>:HORizonatal:SPAN
:TVARiation<x>:MARKer?
:TVARiation<x>:MARKer:{HIGH|LOW} Sets the position of the high/low marker or queries the current setting.
:TVARiation<x>:MARKer:{LEFT|RIGHt}
:TVARiation<x>:MARKer:{LVALue?|RVALue?}
:TVARiation<x>:MARKer[:STATe]
:TVARiation<x>:VERTical?
:TVARiation<x>:VERTical:CENTer
:TVARiation<x>:VERTical:SPAN
UNIT Group
:UNIT?
:UNIT:VOLTage
:UNIT:TIME
:UNIT:FREQuency
Common Command Group
*CAL?
*CLS
*ESE
*ESR?
*IDN?
*OPC
*OPC?
*RST
*SRE
*STB?
*TRG?
*TST?
*WAI
IM 704510-17E
Function
Queries all settings related to time variation.
Queries all settings related to the horizontal axis (X-axis) of the time
variation display.
Sets the left end of the horizontal axis (X-axis) scale or queries the current
setting.
Sets the span of the horizontal axis (X-axis) scale or queries the current
setting.
Queries all settings related to the marker.
Sets the position of the left/right marker or queries the current setting.
Queries the measured value at the left/right marker position.
Turns ON/OFF the marker cursor or queries the current setting.
Queries all settings related to the vertical axis (Y-axis).
Queries the center value of the vertical axis (Y-axis).
Queries the span of the vertical axis (Y-axis).
Queries the default unit of voltage, time and frequency.
Sets the default unit of voltage or queries the current setting.
Sets the default unit of time or queries the current setting.
Sets the default unit of frequency or queries the current setting.
Performs calibration and queries the result.
Clears the standard event register, extended event register, and error queue. 4-72
Sets the standard event enable register or queries the current setting.
Queries the standard event register and clears the register.
Queries the instrument model.
Sets the bit 0 (OPC bit) of the standard event register to 1 upon the
completion of the specified overlap command.
Creates a response upon the completion of the specified overlap command. 4-72
Resets the settings.
Sets the service request enable register or queries the current setting.
Queries the status byte register.
Executes single measurement.
Performs a self-test and queries the result.
Holds the subsequent command until the completion of the specified
overlap operation.
4.1 List of Commands
Page
4-69
4-69
4-70
4-70
4-70
4-70
4-70
4-70
4-70
4-70
4-70
4-71
4-71
4-71
4-71
4-71
4-72
4-72
4-72
4-72
4-72
4-73
4-73
4-73
4-73
4-73
4-73
4-7