Wiring and Connecting the 100W High Voltage Power Supply to the 7705 SAR-A
Step 2. Insert the –VDC black wire from the 100W High Voltage Power Supply into the
Step 3. Insert the +VDC red wire from the 100W High Voltage Power Supply into the
Step 4. For redundant power supply configurations, repeat steps 1 to 3.
Step 5. Remove the protective plastic cap from the NEMA 5-15P plug connector on the
Step 6. Attach the appropriate power cord to the AC power input end of the power supply:
Step 7. Plug the AC power cord into the grounded AC power outlet.
Wiring and Connecting DC Power via the 100W High
Voltage Power Supply
Required tools and hardware:
Follow these steps to wire and connect a DC power supply to the –48 VDC power feed inputs
on the 7705 SAR-A terminal block via the 100W High Voltage Power Supply.
shows the terminal connections;
Step 1. Prepare the open-ended DC output wire from the 100W High Voltage Power
92
Key
Description
1
Copper wire
2
0.35 in. (9 mm) of outer shielding removed
–Batt wire receptacle on the router. Tighten the screw to a torque of
3.54 to 4.42 lbf-in (0.4 to 0.5 N
+Batt wire receptacle on the router. Tighten the screw to a torque of
3.54 to 4.42 lbf-in (0.4 to 0.5 N
power supply.
a. For North American power outlets, use the North American AC power cord.
b. For European power outlets, use the 240V European AC power cord.
•
one 100W High Voltage Power Supply (two are required for redundant power
configurations)
•
wire stripper
•
torque driver for slot screws; No. 2 slotted blade width, 0.125 in (3.2 mm)
Supply by stripping 0.35 in. (9 mm) of insulation from each power cable at the
router end, as shown in
Table 24: DC Power Cable Descriptions
.
m) maximum.
.
m) maximum.
Table 23
identifies the key items in the figure.
Figure
21.
Table 24
7705 SAR-A Chassis Installation Guide
identifies the key items in the figure.
Figure 20