High-Voltage DC Power Requirements

AC Power Requirements

Compliance

See
7705 SAR-A Chassis Installation Guide
Warning: Bare conductors must be coated with an appropriate antioxidant compound
before crimp connections are made. All unplated connectors, braided straps, and bus bars
must be brought to a bright finish and then coated with an antioxidant before they are
connected.
Note: In order to comply with the GR-1089 Lightning Criteria for Equipment interfacing with
AC Power Ports, an external Surge Protective Device is intended to be used at the AC input
of the router or building power service entrance as per the NEC.
For the 100W High Voltage Power Supply, the means of disconnect is the IEC inlet
on the unit.
A DC-rated circuit breaker or fuse with recommended current rating of 20 A
(maximum) must be provided in the hot side of the supply line. A ganged breaker that
simultaneously disconnects both sides of the supply line is also acceptable.
The minimum size/AWG power conductor for the DC input connections must be
based on the application, and on the local codes, practices, and regulations applicable
for the region.
All power cables used on the 100W High Voltage Power Supply must meet local
safety codes.
A standard 120 or 240 VAC outlet is required.
All power cords used on the 100W High Voltage Power Supply must meet local
safety codes.
Standards and Protocol Support
100W High Voltage Power Supply Connections
for compliance information.