Service aggregation router. sar-a chassis
Table of Contents

Advertisement

swsim4># show>chassis
===============================================================================
Chassis Information
===============================================================================
Hardware Data
-------------------------------------------------------------------------------
Both variants of the 7705 SAR-A run the same operating system software. The difference
between the platforms is their hardware configuration. The term 7705 SAR-A is used in this
document as a generic reference to both variants of the chassis. Where hardware differences
occur, the chassis variant is specified.
The 7705 SAR-A has preassigned parameters. The software and hardware architecture is
similar to other SAR products in that the IOM is a virtual entity, existing in software and
supported by the system hardware. The I/O ports are grouped and virtualized into slots
(MDAs) for convenience of assignment. The result of this design is that the CLI identifiers
for the IOM and MDAs have been preset. Also, the system hardware is permanently built into
the chassis. This preset arrangement of system parameters is considered to be a "fixed"
configuration. The fixed configuration of the 7705 SAR-A restricts the router to "port-level
provisioning; however, the IOM and MDA numbering must still be specified in CLI
commands.
The 7705 SAR-A replaces the CSM module found in the 7705 SAR-8 and 7705 SAR-18 with
a control and switching functional block that is integrated into the chassis and does not need
to be provisioned. It appears in the CLI as CSM A. The control and switching functions
include the console and management interfaces, the synchronization interfaces, and system
LEDs.
7705 SAR-A Chassis Installation Guide
Name
Type
Location
Coordinates
CLLI code
Number of slots
Number of ports
Critical LED state
Major LED state
Minor LED state
Over Temperature state
Base MAC address
Part number
CLEI code
Serial number
Manufacture date
Manufacturing variant
Manufacturing string
Manufacturing deviations
Time of last boot
Current alarm state
: swsim4
: 7705 SAR-A (Eth XOR)
:
:
:
: 2
: 12
: Off
: Off
: Off
: OK
: a4:9a:ff:00:00:00
: Sim Part#
: Sim CLEI
: swsim4
: 01012003
: ch1: 1471 ch2: 1491
: Sim MfgString swsim4
: Sim MfgDeviation swsim4
: 2013/01/22 20:04:52
: alarm cleared