Parameter Setting Area For Slave Function - Mitsubishi Electric QJ71DN91 User Manual

Melsec q series devicenet master-slave module
Hide thumbs Also See for QJ71DN91:
Table of Contents

Advertisement

3 SPECIFICATIONS

3.4.9 Parameter setting area for slave function

Buffer memory
address (Hex.)
Slave function receive-bytes (input size)
060E
H
setting area
Slave function transmit-bytes (output size)
060F
H
setting area
3 - 40
Parameters for the slave function are set in this area.
(1) Slave Function Receive-Bytes Setting Area (address:
060E
/1550)/Slave Function Transmit-Bytes Setting Area (address:
H
060F
/1551)
H
Input/output points for the slave function are set.
For saving parameters to a flash ROM, refer to Section 8.2 (2).
Table 3.28 Slave function parameters
Item
Set a size of I/O data that can be received for the slave function.
(Setting range: 0 to 128 bytes, Default: 8 bytes)
Set a size of I/O data that can be sent for the slave function.
(Setting range: 0 to 128 bytes, Default: 8 bytes)
MELSEC-Q
Description
3 - 40

Advertisement

Table of Contents
loading

Table of Contents