5 SETUP AND PROCEDURES BEFORE OPERATION

5.6 Switch setting for intelligent function module

Switch No.
Switch 1
Pulse output mode
Pulse output logic selection
Switch 2
Deviation counter clear output
logic selection
Zero signal input logic selection
Switch 3
Rotation direction setting
Near-point dog signal input logic
Switch 4
selection
Switch 5
Setting item
Pulse output mode
Pulse output logic selection
Deviation counter clear output
logic selection
Zero signal input logic selection
Rotation direction setting
Near-point dog signal input
logic selection
5 - 14
Downloaded from
ManualsNet.com
By making the intelligent function module switch setting, the QD70 allows you to set
the pulse output mode, external I/O signal logic and rotation direction. (However, you
cannot set the speed-position switching signal (CHG) logic. It is fixed at the negative
logic.)
Make the intelligent function module switch setting in the "I/O assignment setting" PLC
parameter of the QCPU using GX Developer.
• There are intelligent function module switches 1 to 5, which are set with 16-bit data.
• When you do not make the intelligent function module switch setting, switches 1 to 5
default to 0.
The settings made with the intelligent function module switches are made valid after
power-on or programmable controller CPU reset. You cannot change the settings
during operation.
Setting item
[Setting example]
Axis 8
Axis 7
PULSE/SIGN mode
+
-
-
+
-
-
Reverse run pulse output increases the
current feed value.
+
+
search engine
Setting details/bit assignment
b15
b8 b7
8)
7)
6)
5)
1 to 8 indicate the axis Nos.
00 : CW/CCW mode
01 : PULSE/SIGN mode
b15
b8 b7
8)
7)
6)
5)
4)
3)
2)
1)
8)
Deviation counter clear output logic
selection
1 to 8 indicate the axis Nos.
0 : Negative logic
1 : Positive logic
b15
b8 b7
8)
7)
6)
5)
4)
3)
2)
1)
8)
Rotation direction setting
1 to 8 indicate the axis Nos.
<Rotation direction setting>
0 : Forward run pulse output increases
the current feed value.
1 : Reverse run pulse output increases
the current feed value.
b15
b8 b7
8)
1 to 8 indicate the axis Nos.
0 : Negative logic
1 : Positive logic
Vacant
Setting details
Axis 6
Axis 5
Axis 4
+
-
+
-
+
-
-
-
+
Forward run pulse output increases the
-
-
-
MELSEC-Q
b0
4)
3)
2)
1)
b0
7)
6)
5)
4)
3)
2)
1)
Pulse output logic selection
b0
7)
6)
5)
4)
3)
2)
1)
Zero signal input logic selection
<Zero signal input logic selection>
0 : Negative logic
1 : Positive logic
b0
7)
6)
5)
4)
3)
2)
1)
Axis 3
Axis 2
Axis 1
PULSE F
CW/CCW mode
PULSE R
-
+
-
+
-
+
CLEAR
+
+
+
PGO
current feed value.
-
+
+
DOG
+: Positive logic -: Negative logic
Default value
0000
0000
0000
0000
Target
Switch
signal
setting
names
Switch 1:
5500H
Switch 2:
55AAH
Switch 3:
F00FH
Switch 4:
00C3H
5 - 14