APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 5 of 66)
ADDR
REGISTER NAME
070E
IEC103 ASDU 1 Analog Param 3
070F
IEC103 ASDU 1 Analog Factor 3
0710
IEC103 ASDU 1 Analog Offset 3
0711
IEC103 ASDU 1 Analog Param 4
0712
IEC103 ASDU 1 Analog Factor 4
0713
IEC103 ASDU 1 Analog Offset 4
0714
IEC103 ASDU 1 Analog Param 5
0715
IEC103 ASDU 1 Analog Factor 5
0716
IEC103 ASDU 1 Analog Offset 5
0717
IEC103 ASDU 1 Analog Param 6
0718
IEC103 ASDU 1 Analog Factor 6
0719
IEC103 ASDU 1 Analog Offset 6
071A
IEC103 ASDU 1 Analog Param 7
071B
IEC103 ASDU 1 Analog Factor 7
071C
IEC103 ASDU 1 Analog Offset 7
071D
IEC103 ASDU 1 Analog Param 8
071E
IEC103 ASDU 1 Analog Factor 8
071F
IEC103 ASDU 1 Analog Offset 8
0720
IEC103 ASDU 1 Analog Param 9
0721
IEC103 ASDU 1 Analog Factor 9
0722
IEC103 ASDU 1 Analog Offset 9
0723
...Repeated for IEC103 ASDU 2
0742
...Repeated for IEC103 ASDU 3
0761
...Repeated for IEC103 ASDU 4
IEC 103 Commands (Read/Write Setting) (32 modules)
0780
IEC103 Command 1 FUN
0781
IEC103 Command 1 INF
0782
IEC103 Command 1 Param ON
0783
IEC103 Command 1 Param OFF
0784
...Repeated for IEC103 Command 2
0788
...Repeated for IEC103 Command 3
078C
...Repeated for IEC103 Command 4
0790
...Repeated for IEC103 Command 5
0794
...Repeated for IEC103 Command 6
0798
...Repeated for IEC103 Command 7
079C
...Repeated for IEC103 Command 8
07A0
...Repeated for IEC103 Command 9
07A4
...Repeated for IEC103 Command 10
07A8
...Repeated for IEC103 Command 11
07AC
...Repeated for IEC103 Command 12
07B0
...Repeated for IEC103 Command 13
07B4
...Repeated for IEC103 Command 14
07B8
...Repeated for IEC103 Command 15
07BC
...Repeated for IEC103 Command 16
07C0
...Repeated for IEC103 Command 17
07C4
...Repeated for IEC103 Command 18
07C8
...Repeated for IEC103 Command 19
07CC
...Repeated for IEC103 Command 20
07D0
...Repeated for IEC103 Command 21
07D4
...Repeated for IEC103 Command 22
07D8
...Repeated for IEC103 Command 23
07DC
...Repeated for IEC103 Command 24
07E0
...Repeated for IEC103 Command 25
07E4
...Repeated for IEC103 Command 26
GE Multilin
RANGE
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 65535
0 to 65.535
-32768 to 32767
0 to 255
0 to 255
0 to 64
0 to 64
C60 Breaker Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F600
---
0.001
F001
---
1
F002
---
1
F001
---
1
F001
---
1
F631
---
1
F631
DEFAULT
0
1000
0
0
1000
B
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
1000
0
0
0
0 (OFF)
0 (OFF)
B-13