APPENDIX B
Table B–10: MODBUS MEMORY MAP (Sheet 35 of 66)
ADDR
REGISTER NAME
74AF
Disconnect Switch 1 Phase A / Three-pole Opened
74B1
Disconnect Switch 1 Phase B Closed
74B3
Disconnect Switch 1 Phase B Opened
74B5
Disconnect Switch 1 Phase C Closed
74B7
Disconnect Switch 1 Phase C Opened
74B9
Disconnect Switch 1 Operate Time
74BA
Disconnect Switch 1 Alarm Delay
74BC
Disconnect Switch 1 Events
74BD
Reserved (2 items)
74BF
...Repeated for Disconnect Switch 2
74DE
...Repeated for Disconnect Switch 3
74FD
...Repeated for Disconnect Switch 4
751C
...Repeated for Disconnect Switch 5
753B
...Repeated for Disconnect Switch 6
755A
...Repeated for Disconnect Switch 7
7579
...Repeated for Disconnect Switch 8
7598
...Repeated for Disconnect Switch 9
75B7
...Repeated for Disconnect Switch 10
75D6
...Repeated for Disconnect Switch 11
75F5
...Repeated for Disconnect Switch 12
7614
...Repeated for Disconnect Switch 13
7633
...Repeated for Disconnect Switch 14
7652
...Repeated for Disconnect Switch 15
Thermal Overload Protection (Read/Write Settings) (2 modules)
7788
Thermal Protection 1 Function
7789
Thermal Protection 1 Source
778A
Thermal Protection 1 Base Current
778B
Thermal Protection 1 K Factor
778C
Thermal Protection 1 Trip Time Constant
778D
Thermal Protection 1 Reset Time Constant
778E
Thermal Protection 1 Minimum Reset Time
778F
Thermal Protection 1 Reset
7791
Thermal Protection 1 Block
7793
Thermal Protection 1 Target
7794
Thermal Protection 1 Events
7795
Reserved (2 items)
7797
Repeated for Thermal Protection 2
Ohm Inputs (Read/Write Setting) (2 modules)
77F8
Ohm Inputs 1 Function
77F9
Ohm Inputs 1 ID
77FF
Ohm Inputs 1 Reserved (9 items)
7808
...Repeated for Ohm Inputs 2
Phasor Measurement Unit Recorder Config Counter Command (Read/Write Command) (2 modules)
781A
PMU 1 Recorder Clear Config Counter
781B
...Repeated for PMU 2
Phasor Measurement Unit One-shot Command (Read/Write Setting)
788C
PMU One-shot Function
788D
PMU One-shot Sequence Number
788E
PMU One-shot Time
Phasor Measurement Unit Recording Values (Read Only) (2 modules)
7890
PMU 1 Available Records
7891
PMU 1 Second Per Record
7893
PMU 1 Last Cleared Date
7895
...Repeated for PMU 2
GE Multilin
RANGE
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 4294967295
0 to 65.535
0 to 65.535
0 to 1
---
0 to 1
0 to 5
0.2 to 3
1 to 1.2
0 to 1000
0 to 1000
0 to 1000
0 to 4294967295
0 to 4294967295
0 to 2
0 to 1
---
0 to 1
---
0 to 65535
0 to 1
0 to 1
0 to 99
0 to 235959
0 to 65535
0 to 6553.5
0 to 400000000
C60 Breaker Protection System
B.4 MEMORY MAPPING
UNITS
STEP
FORMAT
---
1
F300
---
1
F300
---
1
F300
---
1
F300
---
1
F300
s
0.001
F001
s
0.001
F003
---
1
F102
---
---
F001
---
1
F102
---
1
F167
pu
0.01
F001
---
0.05
F001
min.
1
F001
min.
1
F001
min.
1
F001
---
1
F300
---
1
F300
---
1
F109
---
1
F102
---
---
F001
---
1
F102
---
---
F205
---
1
F001
---
1
F126
---
1
F102
---
1
F001
---
1
F050
---
1
F001
---
0.1
F003
---
1
F050
DEFAULT
0
0
0
0
0
B
70
0
0 (Disabled)
0
0 (Disabled)
0 (SRC 1)
80
110
45
45
20
0
0
0 (Self-reset)
0 (Disabled)
0
0 (Disabled)
"Ohm Ip 1 "
0
0 (No)
0 (Disabled)
1
0
0
0
0
B-43