Print item
PARTS CNT.
[Value of each
parts counter]
COGFF
CONDITION
PARAM0-F
PARAM0-B
LF SCALE
LF-A
adjustment value (user
LF-B
value)
SCALE-A
SCALE-B
PV AUTO JUDGE
T-7-200
Print content
Status
Number of days after set
Count
Life threshold
Usage
Cumulative count
Cogging FF result
Parameters 1
Parameters 2
LF8 pass
LF1 pass
Scale clean
Scale fast
Ink reduction mode
Printed value
OK/W1/W2/E
Unit: Days
Unit: %
0: Disabled
1: Enabled
2: Check required
3: Adjust reruired
REF: Motor error (6 digits)
PHASE: Phase (3 digits)
AMP: Amplitude (3 digits)
RATE: Decay rate (3 digits)
REF: Motor error (6 digits)
PHASE: Phase (3 digits)
AMP: Amplitude (3 digits)
RATE: Decay rate (3 digits)
ON (NORMAL/LOW only when ON)/Number of times
OFF is entered
Chapter 7