4) CLEAR: Counters related to counter initialization
Display
CLR-INK CONSUME
CLR-MTC EXC.
CLR-HEAD L EXC.
CLR-HEAD R EXC.
CLR Wia-1 EXC.
CLR Wib-1 EXC.
CLR CR-1 EXC.
CLR CR-2 EXC.
CLR CR-3 EXC.
CLR CR-4 EXC.
CLR CR-5 EXC.
CLR SP-1 EXC.
CLR PG-1 EXC.
CLR HMa-1 EXC.
CLR PL-1 EXC.
CLR PS-1 EXC.
CLR Mi-1 EXC.
CLR MS-1 EXC.
CLR CT-1 EXC.
CLR-FACTORY CNT.
5) EXCHANGE: Counters related to parts replacement
MTC EXC.
HEAD L EXC.
HEAD R EXC.
BOARD EXC.(M/B)
Wia-1 EXC.
Wib-1 EXC.
CR-1 EXC.
CR-2 EXC.
CR-3 EXC.
CR-4 EXC.
CR-5 EXC.
SP-1 EXC.
PG-1 EXC.
HMa-1 EXC.
PL-1 EXC.
PS-1 EXC.
Mi-1 EXC.
MS-1 EXC.
CT-1 EXC.
Description
Cumulative count of ink section consumption amount clearing
Cumulative count of maintenance cartridge replacement count clearing
Cumulative count of printhead L replacement count clearing
Cumulative count of printhead R replacement count clearing
Cumulative count of unit Wia-1(suction fan) replacement count clearing
Cumulative count of unit Wib-1(platen duct) replacement count clearing
Cumulative count of unit CR-1(carriage unit bushing) replacement count
clearing
Cumulative count of unit CR-2(fexible cable unit) replacement count clearing Times
Cumulative count of unit CR-3(linear encoder sensor/linear scale/shaft cleaner)
replacement count clearing
Cumulative count of unit CR-4(carriage height changing cam) replacement
count clearing
Cumulative count of unit CR-5(multi sensor) replacement count clearing
Cumulative count of unit SP-1(ink tube unit) replacement count clearing
Cumulative count of unit PG-1(purge unit) replacement count clearing
Cumulative count of unit HMa-1(head management sensor) replacement count
clearing
Cumulative count of unit PL-1(feed motor) replacement count clearing
Cumulative count of unit PS-1(spur) replacement count clearing
Cumulative count of unit Mi-1(mist fan/mist filter) replacement count clearing Times
Cumulative count of unit MS-1(multi sensor) replacement count clearing
Cumulative count of unit CT-1(cutter) replacement count clearing
For factory
Display
Maintenance cartridge replacement count
Printhead L replacement count
Printhead R replacement count
Main controller PCB replacement count
Wia-1(suction fan) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS Wia-1])
Wib-1(platen duct) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS Wib-1])
CR-1(carriage unit bushing) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS CR-1])
CR-2(fexible cable unit) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS CR-2])
CR-3(linear encoder sensor/linear scale/shaft cleaner) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS CR-3])
CR-4(carriage height changing cam) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS CR-4])
CR-5(multi sensor) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS CR-5])
SP-1(ink tube unit) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS SP-1])
PG-1(purge unit) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS PG-1])
HMa-1(head management sensor) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS HMa-1])
PL-1(feed motor) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS PL-1])
PS-1(spur) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS PS-1])
Mi-1(mist fan/mist filter) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS Mi-1])
MS-1(multi sensor) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS MS-1])
CT-1(cutter) replacement count
(Count of executing [INITIALIZE] > [PARTS COUNTER] > [PARTS CT-1])
T-7-160
Unit
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
T-7-161
Description
Remarks
Calibration error index, This counter
synchronizes with CLR CR-5 EXC.
Unit
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times
Times