Parameter Settings - Bosch Rexroth EFC 3600 Operating Instructions Manual

Frequency converter
Hide thumbs Also See for Rexroth EFC 3600:
Table of Contents

Advertisement

DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
8

Parameter Settings

8.1
Group b0: System Parameters
b0.00
User password
Setting range
0 ~ 65535
Minimum unit
1
Factory default
0
● Activate the user password protection: the default value of the password is 0 (inac‐
tive), enter a new number between 1 and 65535 to activate the user password pro‐
tection.
● Modify the password: enter the correct user password and then set a new number
between 1 and 65535 to modify the user password.
● Delete password: enter the correct user password and set [b0.00]=0 to deactivate
the password.
● Once a user password is set, users may only read but not modify nor
copy parameters if an incorrect password is entered.
● Please contact the manufacture if you forget the set password.
● User password protection will not affect frequency modification with ▲/▼
keys in RUN mode. It means that the frequency may still be saved ac‐
cording to the selected saving mode when the frequency setting source
is via digital setting. See descriptions in parameter [b1.01].
b0.01
Manufacturer password
Setting range
0 ~ 65535
Minimum unit
1
Factory default
0
Manufacturer password is only available for service.
b0.02
Access authority setting
Setting range
0 ~ 4
Minimum unit
1
Factory default
0
Used to define the parameter access authority. Visible parameter groups differ in the
display when the settings of this parameter are different.
● 0: Basic parameters. In this mode, only parameters in group b (b0 and b1) are visi‐
ble.
Bosch Rexroth AG
Parameter Settings
53/235