Bosch Rexroth EFC 3600 Operating Instructions Manual page 150

Frequency converter
Hide thumbs Also See for Rexroth EFC 3600:
Table of Contents

Advertisement

Bosch Rexroth AG
Electromagnetic Compatibility (EMC)
Minimum immunity requirements for PDSs intended for use in the second environment
Port
Phenomenon
ESD
Radio-frequency electro‐
magnetic field, amplitude
modulated
Fast transient-burst
Surge 1.2/50 μs, 8/20 μs
Conducted radio-frequen‐
cy common mode
Fast transient-burst
Fast transient-burst
Conducted radio-frequen‐
cy common mode
Fast transient-burst
Conducted radio-frequen‐
cy common mode
Fig.11-1: Minimum immunity requirements for PDSs intended for use in the second
environment
148/235
DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
Basic
standard
for test
method
4 kV CD or 8 kV AD
IEC
61000-4-2
if CD impossible
80 to 1000 MHz 10
V/m
IEC
1.4 to 2.0 GHz 3 V/m
61000-4-3
2.0 to 2.7 GHz 1 V/m
80 % AM (1 kHz)
IEC
2 kV/5 kHz
61000-4-4
IEC
1 kV
, 2 kV
a
61000-4-5
0.15 MHz to 80 MHz
IEC
10 V
61000-4-6
80 % AM (1 kHz)
2 kV/5 kHz
IEC
61000-4-4
Capacitive clamp
1 kV/5 kHz
IEC
61000-4-4
Capacitive clamp
0.15 MHz to 80 MHz
IEC
10 V
61000-4-6
80 % AM (1 kHz)
2 kV/5 kHz
IEC
61000-4-4
Capacitive clamp
0.15 MHz to 80 MHz
IEC
10 V
61000-4-6
80 % AM (1 kHz)
Performance
Level
(acceptance)
criterion
b
B
A
B
B
A
B
B
A
B
A

Hide quick links: