Bosch Rexroth AG
Block Diagram of Main Functions

7.8 Restore ASF Parameter

User can restore ASF parameter setting to default via F1.00, by doing this follow-
ing EFC parameters will be re-set to ASF default values as well. Please reference
chapter 8.6 "Auto-modified EFC Parameters in FcP Initialization" on page 62
for more details.
Additionally, if b0.10 is executed to restore EFC parameters, please make sure to
re-execute F1.00 = 1 to restore all ASF parameters to default values.
Fig. 7-11: ASF parameter restore to default
By restoring ASF parameter (setting F1.00 = 1), the value of parame-
ter F1.15 and F1.16 will NOT be restored. For CytroPac application,
after restoring ASF parameter (setting F1.00 = 1), parameter F1.20
need to set according to different type of CytroPac applications in
order to quickly configure setting of CytroPac.