Rexroth Frequency Converter EFC 3600
Factory default
Depends on model
S2.11
Rotator resistance
Setting range
0.00 ~ 50.00 Ω
Minimum unit
0.01 Ω
Factory default
Depends on model
S2.12
Leakage inductance
Setting range
0.00 ~ 200.00 mH
Minimum unit
0.01 mH
Factory default
Depends on model
S2.13
Mutual inductance
Setting range
0.0 ~ 3000.0 mH
Minimum unit
0.1 mH
Factory default
Depends on model
S2.14
No-load current
Setting range
0.00 ~ [S2.04]
Minimum unit
0.01 A
Factory default
Depends on model
S2.15
Physical data calculation
Setting range
0 ~ 3
Minimum unit
1
Factory default
0
The motor parameters ([S2.00] ~ [S2.05]) must be set before using "Physical data cal‐
culation" [S2.15]. The necessary information can be found on the nameplate of motor.
● [S2.15]=0: No action.
● [S2.15]=1: Calculation. After the calculation is finished, parameters [S2.10] ~ [S2.14]
will be updated.
● [S2.15]=2: Automatic adjustment while the motor is in static mode.
● [S2.15]=3: Automatic adjustment while the motor is rotating.
S2.20
Sensor type
Setting range
0: PTC; 1: NTC
Minimum unit
1
Factory default
0
S2.21
Input channel of motor temperature
Setting range
0: Invalid; 1: Analog input voltage
Minimum unit
1
Bosch Rexroth AG
Parameter Settings
83/235