Bosch Rexroth EFC 3600 Operating Instructions Manual page 65

Frequency converter
Hide thumbs Also See for Rexroth EFC 3600:
Table of Contents

Advertisement

DOK-RCON03-EFC-3600***-IT01-EN-P
Rexroth Frequency Converter EFC 3600
b1.11
Operating panel controls direction
Setting range
0 ~ 1
Minimum unit
1
Factory default
0
This parameter is only applicable for operations via the operating panel.
● 0: Forward rotation
● 1: Reverse rotation
The relationship between [b1.10] and [b1.11] is:
Fig.8-3: Relationship between [b1.10] and [b1.11]
Direction control [b1.10]
0
Both directions
1
Forward only
2
Reverse only
3
Inverse default direction
For "STOP with error", please see
page
128.
Normally, each RUN / STOP command source has its own direction command source.
The generated direction is further controlled by internal direction control ([b1.10]).
Frequency source
Multi-speed
Default direction [b1.11]
Forward
Reverse
Forward
Reverse
Forward
Reverse
Forward
Reverse
RUN / STOP command
source
Operating panel
2-wire / 3-wire running control
[E0.00]
Communication
Parameter Settings
STOP with error
STOP with error
chapter 9.5 "Diagnosis on Errors" on
Direction command source
Defined by multi-speed / PLC
configuration
2-wire / 3-wire running control
[E0.00]
Communication
Bosch Rexroth AG
Final direction
Forward
Reverse
Forward
Reverse
Reverse
Forward
63/235

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents