5.12 Power Supplies

5.12.1 AC Line Filter
(Estimated Replacement Time: 15 minutes)
1. Remove the rear right skin. Refer to
Right Skin (ignitor/blower compartment), on
page
5-7.
2. Remove the front top lid. Refer to
Top Lid, on page
3. Open the lamp door. Refer to
Door, on page
4. Rotate the rear top lid to gain access to the
igniter/blower compartment. Refer to
Rear Top Lid, on page
5. Remove the two hex nuts from the bracket the
AC line filter is secured to, which is secured to
the firewall. (Figure 5-45)
6. Disconnect the two harnesses from the AC line
filter.
7. Remove the AC line filter.
CP2230 Service Manual
020-100562-06 Rev. 1 (05-2016)
Figure 5-44 LVPS Compartment