Download Print this page

Verify The Status Of The System Hardware, Storage Controller, And Disks - Dell EMC ScaleIO Ready Node 14G Inspection Manual

Hide thumbs Also See for EMC ScaleIO Ready Node 14G:

Advertisement

Maintenance
Verify the status of the system hardware, storage
controller, and disks
Maintenance
6
Verify the status of the system hardware, storage controller, and disks on a ScaleIO
Ready Node server.
Before you begin
Ensure that you know:
The IP address of the BMC (iDRAC) port
l
The username and password for the BMC (iDRAC) portal (default username and
l
password are root and password)
Procedure
1. From a browser, go to http://
The DELL Console Login window is displayed.
2. Type the user name and password, then click Login.
The Dashboard displays the high-level status of all hardware devices in the
System Health pane.
In an ideal scenario, all hardware sensors should appear in green.
3. To view the event log (SEL log), on the Dashboard select Maintenance
System Event Logs.
The System Event Log pane is displayed with color-coded severity levels.
4. Ensure that any power supply- and fan-related events in the event log are non-
repetitive. Repetitive events may be due to the intermittent nature of faults,
such as poor physical connections.
For repetitive events, it is recommended that you remove the relevant hardware
module and replace it in its socket.
5. In the navigation pane, select Storage
A table displays the controller-related information, with the controller type in
the Name column. For example:
PERC H740P Adapter (PCI Slot 4)
PERC H740P Mini (Embedded) or PERC H730 Mini (Embedded)
PERC H740P Mini (Embedded) or PERC H730 Mini (Embedded)
6. In the navigation pane, select Storage
A table displays information regarding the physical disks, and an option to
Blink/Unblink the selected disk.
7. Verify that no disk is in the failed state.
If any of the disks is failed, refer to the relevant disk FRU.
8. In the navigation pane, select System.
9. In the Inventory pane, verify that the server drivers and firmware in the
Firmware Inventory list match the required versions, as published in the
ScaleIO Ready Node Driver and Firmware
<BMC/iDRAC_IP_address> .
Overview
Controller.
>
>
Physical Disks.
>
Matrix.
>

Advertisement

loading