Omron 3G3AX-MX2-ECT User Manual page 140

Mx2 series ethercat communication unit
Hide thumbs Also See for 3G3AX-MX2-ECT:
Table of Contents

Advertisement

Sub-
Index
index
3013
32
hex
hex
3013
33
hex
hex
3013
34
hex
hex
3013
35
hex
hex
3013
37
hex
hex
3013
38
hex
hex
3013
39
hex
hex
3013
3A
hex
hex
3013
3B
hex
hex
3013
3C
hex
hex
3013
3D
hex
hex
3013
3E
hex
hex
3013
3F
hex
hex
3013
40
hex
hex
3013
41
hex
hex
3013
42
hex
hex
3013
43
hex
hex
3013
44
hex
hex
3013
45
hex
hex
3013
46
hex
hex
3013
47
hex
hex
3013
49
hex
hex
EtherCAT Communication Unit USER'S MANUAL (3G3AX-MX2-ECT)
Register
Function name
No.
130B
Overvoltage/Overcurrent
hex
Restart Count Selection
130C
Overvoltage/Overcurrent
hex
Restart Standby Time
130D
Electronic Thermal
hex
Level 1
130E
Electronic Thermal
hex
Characteristics
Selection 1
1310 hex
Free-electronic
Thermal Frequency 1
1311 hex
Free-electronic
Thermal Current 1
1312 hex
Free-electronic
Thermal Frequency 2
1313 hex
Free-electronic
Thermal Current 2
1314 hex
Free-electronic
Thermal Frequency 3
1315 hex
Free-electronic
Thermal Current 3
1316 hex
Overload Limit 1
Selection
1317 hex
Overload Limit 1 Level
1318 hex
Overload Limit 1
Parameter
1319 hex
Overload Limit 1
Selection 2
131A
Overload Limit 1
hex
Level 2
131B
Overload Limit 1
hex
Parameter 2
131C
Overcurrent
hex
Suppression Selection
131D
Frequency Pull-in
hex
Restart Level
131E
Frequency Pull-in
hex
Restart Parameter
131F hex
Starting Frequency at
Frequency Pull-in
Restart Selection
1320 hex
Soft Lock Selection
1322 hex
Motor Cable Length
Code Selection
Parameter
R/W
Monitor and setting items
No.
b010
RW
1 to 3
b011
RW
3 to 1000
b012
RW
200 to 1000
b013
RW
00: Reduced torque characteristics
01: Constant torque characteristics
02: Free setting
b015
RW
0 to Free-electronic Thermal
Frequency 2
b016
RW
0.00 to rated current
b017
RW
Free-electronic Thermal Frequency
1 to Free Setting, Electric Thermal
Frequency 3
b018
RW
0.00 to rated current
b019
RW
Free-electronic Thermal Frequency
2 to 400 (1000)
b020
RW
0.00 to rated current
b021
RW
00: Disabled
01: Enabled during
acceleration/constant speed
02: Enabled during constant speed
03: Enabled during
acceleration/constant speed
(accelerated during
regeneration)
b022
RW
200 to 2000
b023
RW
1 to 30000
b024
RW
00: Disabled
01: Enabled during
acceleration/constant speed
02: Enabled during constant speed
03: Enabled during
acceleration/constant speed
(accelerated during
regeneration)
b025
RW
200 to 2000
b026
RW
1 to 30000
b027
RW
00: Disabled
01: Enabled
b028
RW
200 to 2000
b029
RW
1 to 30000
b030
RW
00: Frequency at interruption
01: Max. frequency
02: Set frequency
b031
RW
00: Data other than b031 cannot be
changed when terminal SFT is
ON.
01: Data other than b031 and the
set frequency cannot be
changed when terminal SFT is
ON.
02: Data other than b031 cannot be
changed.
03: Data other than b031 and the
set frequency cannot be
changed.
10: Data can be changed during
RUN.
b033
RW
5 to 20
Appendices
Data
PDO
resolution
map
1 [time]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
0.1 [%]
Possible
(TxPDO)
Possible
(TxPDO)
1 [Hz]
Possible
(TxPDO)
0.01 [%]
Possible
(TxPDO)
1 [Hz]
Possible
(TxPDO)
0.01 [%]
Possible
(TxPDO)
1 [Hz]
Possible
(TxPDO)
0.01 [%]
Possible
(TxPDO)
Possible
(TxPDO)
0.01 [%]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
Possible
(TxPDO)
0.01 [%]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
Possible
(TxPDO)
0.01 [%]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
Possible
(TxPDO)
Possible
(TxPDO)
Possible
(TxPDO)
A-19