Appendices
Sub-
Index
index
3012
65
hex
hex
3012
66
hex
hex
3012
6A
hex
hex
3012
6B
hex
hex
3012
6C
hex
hex
3012
6D
hex
hex
3012
6E
hex
hex
3012
6F
hex
hex
3012
70
hex
hex
3012
71
hex
hex
3012
72
hex
hex
4012
74
hex
hex
4012
76
hex
hex
4012
78
hex
hex
3012
7A
hex
hex
4012
7B
hex
hex
3012
7D
hex
hex
4012
7E
hex
3012
80
hex
hex
4012
81
hex
hex
3012
83
hex
hex
3012
84
hex
hex
3012
85
hex
hex
3012
86
hex
hex
3012
87
hex
hex
3012
88
hex
hex
3012
89
hex
hex
3012
8A
hex
hex
3012
8B
hex
hex
A-16
Register
Function name
No.
1240 hex
Automatic Torque
Boost Voltage
Compensation Gain 1
1241 hex
Automatic Torque
Boost Slip
Compensation Gain 1
1245 hex
Internal DC Injection
Braking Selection
1246 hex
Internal DC Injection
Braking Frequency
1247 hex
DC Injection Braking
Delay Time
1248 hex
DC Injection Braking
Power
1249 hex
DC Injection Braking
Time
124A
DC Injection Braking
hex
Edge/Level Selection
124B
Startup DC Injection
hex
Braking Power
124C
Startup Internal DC
hex
Injection Braking Time
124D
DC Injection Braking
hex
Carrier Frequency
124F hex
Frequency Upper
Limit 1
1251 hex
Frequency Lower
Limit 1
1253 hex
Jump Frequency 1
1255 hex
Jump Frequency
Width 1
1256 hex
Jump Frequency 2
1258 hex
Jump Frequency
Width 2
1259 hex
Jump Frequency 3
125B
Jump Frequency
hex
Width 3
125C
Acceleration Stop
hex
Frequency
125E
Acceleration Stop
hex
Time
125F hex
PID Selection
1260 hex
PID P Gain
1261 hex
PID I Gain
1262 hex
PID D Gain
1263 hex
PID Scale
1264 hex
PID Feedback
Selection
1265 hex
PID Deviation Reverse
Output
1266 hex
PID Variable Range
Limit
Parameter
R/W
Monitor and setting items
No.
A046
RW
0 to 255
A047
RW
0 to 255
A051
RW
00: Disabled
01: Enabled during stop
02: Output frequency (at A052)
A052
RW
0 to 6000
A053
RW
0 to 50
A054
RW
0 to 100
A055
RW
0 to 600
A056
RW
00: Edge operation
01: Level operation
A057
RW
0 to 100
A058
RW
0 to 600
A059
RW
20 to 150
A061
RW
0
Frequency Lower Limit 1 to
Maximum Frequency 1
A062
RW
0
Starting Frequency to Frequency
Upper Limit 1
A063
RW
0 to 40000 (100000)
A064
RW
0 to 1000 (10000)
A065
RW
0 to 40000 (100000)
A066
RW
0 to 1000 (10000)
A067
RW
0 to 40000 (100000)
A068
RW
0 to 1000 (10000)
A069
RW
0 to 40000
A070
RW
0 to 600
A071
RW
00: Disabled
01: Enabled
02: Reverse output enabled
A072
RW
2 to 2500
A073
RW
0 to 36000
A074
RW
0 to 10000
A075
RW
1 to 9999
A076
R/W
00: Current (FI)
01: Voltage (FV)
02: Modbus communication
(Modbus-RTU)
03: Pulse train frequency
10: Operation function output
A077
RW
00: Disabled
01: Enabled
A078
RW
0 to 1000
EtherCAT Communication Unit USER'S MANUAL (3G3AX-MX2-ECT)
Data
PDO
resolution
map
1 [%]
Possible
1 [%]
Possible
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
1 [%]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
Possible
(TxPDO)
1 [%]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
0.1 [kHz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.01 [Hz]
Possible
(TxPDO)
0.1 [s]
Possible
(TxPDO)
Possible
(TxPDO)
0.01
Possible
0.1 [s]
Possible
0.01 [s]
Possible
0.01
Possible
(TxPDO)
Possible
(TxPDO)
Possible
(TxPDO)
0.1 [%]
Possible
(TxPDO)