APPENDIX A
Table A–1: FLEXANALOG DATA ITEMS (Sheet 5 of 9)
ADDRESS
FLEXANALOG NAME
9222
Synchchk 2 Delta F
9223
Synchchk 2 Delta Phs
9224
Synchchk 3 Delta V
9226
Synchchk 3 Delta F
9227
Synchchk 3 Delta Phs
9228
Synchchk 4 Delta V
9230
Synchchk 4 Delta F
9231
Synchchk 4 Delta Phs
9344
Local IA Mag
9346
Local IB Mag
9348
Local IC Mag
9350
Terminal 1 IA Mag
9352
Terminal 1 IB Mag
9354
Terminal 1 IC Mag
9356
Terminal 2 IA Mag
9358
Terminal 2 IB Mag
9360
Terminal 2 IC Mag
9362
Diff Curr IA Mag
9364
Diff Curr IB Mag
9366
Diff Curr IC Mag
9368
Local IA Angle
9369
Local IB Angle
9370
Local IC Angle
9371
Terminal 1 IA Angle
9372
Terminal 1 IB Angle
9373
Terminal 1 IC Angle
9374
Terminal 2 IA Angle
9375
Terminal 2 IB Angle
9376
Terminal 2 IC Angle
9377
Diff Curr IA Angle
9378
Diff Curr IB Angle
9379
Diff Curr IC Angle
9380
Op Square Curr IA
9382
Op Square Curr IB
9384
Op Square Curr IC
9386
Rest Square Curr IA
9388
Rest Square Curr IB
9390
Rest Square Curr IC
9392
Rest Curr IA
9394
Rest Curr IB
9396
Rest Curr IC
9398
Diff Curr IG Mag
9400
Diff Curr IG Angle
9401
Rest Curr IG
9400
Local IG Mag
9405
Local IG Angle
9406
Terminal 1 IG Mag
GE Multilin
UNITS
DESCRIPTION
Hz
Synchrocheck 2 delta frequency
Degrees
Synchrocheck 2 delta phase
Volts
Synchrocheck 3 delta voltage
Hz
Synchrocheck 3 delta frequency
Degrees
Synchrocheck 3 delta phase
Volts
Synchrocheck 4 delta voltage
Hz
Synchrocheck 4 delta frequency
Degrees
Synchrocheck 4 delta phase
Amps
Local terminal phase A current magnitude
Amps
Local terminal phase B current magnitude
Amps
Local terminal phase C current magnitude
Amps
Remote terminal 1 phase A current magnitude
Amps
Remote terminal 1 phase B current magnitude
Amps
Remote terminal 1 phase C current magnitude
Amps
Remote terminal 2 phase A current magnitude
Amps
Remote terminal 2 phase B current magnitude
Amps
Remote terminal 2 phase C current magnitude
Amps
Differential current phase A magnitude
Amps
Differential current phase B magnitude
Amps
Differential current phase C magnitude
Degrees
Local terminal current phase A angle
Degrees
Local terminal current phase B angle
Degrees
Local terminal current phase C angle
Degrees
Remote terminal 1 current phase A angle
Degrees
Remote terminal 1 current phase B angle
Degrees
Remote terminal 1 current phase C angle
Degrees
Remote terminal 2 current phase A angle
Degrees
Remote terminal 2 current phase B angle
Degrees
Remote terminal 2 current phase C angle
Degrees
Differential current phase A angle
Degrees
Differential current phase B angle
Degrees
Differential current phase C angle
Amps
Phase A operating square current
Amps
Phase B operating square current
Amps
Phase C operating square current
Amps
Phase A restraint square current
Amps
Phase B restraint square current
Amps
Phase C restraint square current
Amps
Restraint current IA
Amps
Restraint current IB
Amps
Restraint current IC
Amps
Differential current IG Magnitude
Degrees
Differential current IG Angle
Amps
Restraint current IG
Amps
Local IG magnitude
Degrees
Local IG angle
Amps
Remote 1 IG magnitude
L30 Line Current Differential System
A.1 PARAMETER LISTS