GE L30 Instruction Manual page 564

Ur series line current differential system
Hide thumbs Also See for L30:
Table of Contents

Advertisement

B.4 MEMORY MAPPING
Bitmask
Error
11
Equipment Mismatch
12
Process Bus Failure
13
Unit Not Programmed
14
System Exception
15
Latching Output Discrepancy
17
Maintenance Alert 01
B
18
SNTP Failure
19
Maintenance Alert
20
Maintenance Alert
21
Maintenance Alert
22
Temperature Monitor
23
Process Bus Trouble
24
Brick Trouble
25
Field RTD Trouble
26
Field TDR Trouble
27
Remote Device Offline
28
Direct Device Offline
29
Maintenance Alert
30
Any Minor Error
31
Any Major Error
33
Maintenance Alert
64
Maintenance Alert
65
IEC 61850 Data Set
66
Aggregator Error
67
Unit Not Calibrated
68
Settings Save Error
69
SRAM Data Error
70
Program Memory
71
Watchdog Error
72
Low On Memory
73
Prototype Firmware
74
Module Failure 01
75
Module Failure 02
76
Module Failure 03
77
Module Failure 04
78
Module Failure 05
79
Module Failure 06
80
Module Failure 07
81
Module Failure 08
82
Module Failure 09
83
Incompatible H/W
84
Module Failure 10
85
Module Failure 11
86
Module Failure 12
87
High ENET Traffic
89
Relay Restart
90
FGM Failure
91
FGM Failure
92
FGM Failure
93
FGM Failure
94
FGM Failure
95
FGM Error
96
Maintenance Alert
B-74
Bitmask
97
98
99
F143
UR_UINT32: 32 BIT ERROR CODE (F141 specifies bit number)
A bit value of 0 = no error, 1 = error
F144
ENUMERATION: FORCED CONTACT INPUT STATE
0 = Disabled, 1 = Open, 2 = Closed
F146
ENUMERATION: MISCELLANEOUS EVENT CAUSES
Bitmask
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
L30 Line Current Differential System
Error
PHY Monitor
Storage Media Alarm
Wrong Transceiver
Definition
Events Cleared
Oscillography Triggered
Date/time Changed
Default Settings Loaded
Test Mode Forcing On
Test Mode Forcing Off
Power On
Power Off
Relay In Service
Relay Out Of Service
Watchdog Reset
Oscillography Clear
Reboot Command
Led Test Initiated
Flash Programming
Fault Report Trigger
User Programmable Fault Report Trigger
---
Reload CT/VT module Settings
---
Ethernet Port 1 Offline
Ethernet Port 2 Offline
Ethernet Port 3 Offline
Ethernet Port 4 Offline
Ethernet Port 5 Offline
Ethernet Port 6 Offline
Test Mode Isolated
Test Mode Forcible
Test Mode Disabled
Temperature Warning On
Temperature Warning Off
Unauthorized Access
System Integrity Recovery
System Integrity Recovery 06
System Integrity Recovery 07
APPENDIX B
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents