GE L30 Instruction Manual page 38

Ur series line current differential system
Hide thumbs Also See for L30:
Table of Contents

Advertisement

2.1 INTRODUCTION
The EnerVista software has a device authentication option on the login screen for accessing the UR device. When the
"Device" button is selected, the UR uses its local authentication database and not the RADIUS server to authenticate the
user. In this case, it uses its built-in roles (Administrator, Engineer, Supervisor, Observer, Operator) as login names and the
associated passwords are stored on the UR device. As such, when using the local accounts, access is not user-attribut-
able.
In cases where user attributable access is required especially to facilitate auditable processes for compliance reasons, use
RADIUS authentication only.
2
When the "Server" Authentication Type option is selected, the UR uses the RADIUS server and not its local authentication
database to authenticate the user.
No password or security information are displayed in plain text by the EnerVista software or UR device, nor are they ever
transmitted without cryptographic protection.
CYBERSENTRY USER ROLES
CyberSentry user roles (Administrator, Engineer, Operator, Supervisor, Observer) limit the levels of access to various UR
device functions. This means that the EnerVista software allows for access to functionality based on the user's logged in
role.
Example: Observer cannot write any settings.
The table lists the roles that are supported and their corresponding capabilities.
Table 2–3: PERMISSIONS BY USER ROLE FOR CYBERSENTRY
Roles
Device Definition
Settings
|------------ Product Setup
|--------------- Security (CyberSentry)
|--------------- Supervisory
|--------------- Display Properties
|---------------
|--------------- Communications
|--------------- Modbus user map
|--------------- Real Time Clock
|--------------- Oscillography
|--------------- Data Logger
|--------------- Demand
|---------------
|---------------
|--------------- Control Pushbuttons
|---------------
|--------------- Flex states
|---------------
|--------------- Direct I/O
|--------------- Tele-protection
|--------------- Installation
|------------ System Setup
2-6
Administrator
Complete access
R
RW
see table notes
RW
Clear relay records
(settings)
RW
RW
RW
RW
RW
RW
RW
User Programmable
LEDs
RW
User Programmable
self test
RW
RW
User programmable
Pushbuttons
RW
RW
User definable dis-
plays
RW
RW
RW
RW
RW
L30 Line Current Differential System
2 PRODUCT DESCRIPTION
Engineer
Operator
Complete access
Command
except for
menu
CyberSentry
Security
R
R
R
R
R
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
RW
R
Supervisor
Observer
Authorizes
Default role
writing
R
R
R
R
see table notes
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
GE Multilin