B.4 MEMORY MAPPING
Table B–10: MODBUS MEMORY MAP (Sheet 18 of 60)
ADDR
REGISTER NAME
Passwords (Read/Write)
402E
Password Access Events
Passwords (Read/Write Setting)
402F
Local Setting Auth
4031
Remote Setting Auth
B
4033
Access Auth Timeout
User Display Invoke (Read/Write Setting)
4040
Invoke and Scroll Through User Display Menu Operand
LED Test (Read/Write Setting)
4048
LED Test Function
4049
LED Test Control
Preferences (Read/Write Setting)
404F
Language
4050
Flash Message Time
4051
Default Message Timeout
4052
Default Message Intensity
4053
Screen Saver Feature
4054
Screen Saver Wait Time
4055
Current Cutoff Level
4056
Voltage Cutoff Level
87L Channel Status (Read Only)
4059
Channel 1 Local Loopback Status
405A
Channel 1 Loop Delay
405B
Channel 1 Number of Lost Packets
405C
Channel 1 Remote Loopback Status
405D
Channel 1 Status
405E
Channel 2 Local Loopback Status
405F
Channel 2 Loop Delay
4060
Channel 2 Number of Lost Packets
4061
Channel 2 Remote Loopback Status
4062
Channel 2 Status
4063
Channel PFLL Status
4064
87L Network Status
87L Channel Status (Read/Write Command)
4065
Channel Status Clear
87L Power System (Read/Write Setting)
4068
Block GPS Time Reference
406A
Channel Asymmetry Compensation
406C
Charging Current Compensation
406D
Local Relay ID
406E
Maximum Channel Asymmetry
406F
Number of Channels
4070
Number of Terminals
4071
Positive Sequence Reactance
4072
Round Trip Time
4073
Terminal 1 ID
4074
Terminal 2 ID
4075
Zero-Sequence Current Removal
4076
Zero Sequence Reactance
Communications (Read/Write Setting)
407D
COM2 Selection
407E
COM1 Minimum Response Time
407F
COM2 Minimum Response Time
4080
Modbus Slave Address
B-26
RANGE
0 to 1
1 to 4294967295
0 to 4294967295
5 to 480
0 to 4294967295
0 to 1
0 to 4294967295
0 to 4
0.5 to 10
10 to 900
0 to 3
0 to 1
1 to 65535
0.002 to 0.02
0.1 to 1
0 to 2
0 to 200
0 to 65535
0 to 2
0 to 2
0 to 2
0 to 200
0 to 65535
0 to 2
0 to 2
0 to 2
0 to 2
0 to 1
0 to 4294967295
0 to 4294967295
0 to 1
0 to 255
0 to 10
1 to 2
2 to 3
0.1 to 65.535
0 to 10
0 to 255
0 to 255
0 to 1
0.1 to 65.535
0 to 3
0 to 1000
0 to 1000
1 to 254
L30 Line Current Differential System
APPENDIX B
UNITS
STEP
FORMAT
---
1
F102
---
1
F300
---
1
F300
min
1
F001
---
1
F300
---
1
F102
---
1
F300
---
1
F531
s
0.1
F001
s
1
F001
---
1
F101
---
1
F102
min
1
F001
pu
0.001
F001
V
0.1
F001
---
1
F134
ms
0.1
F001
---
1
F001
---
1
F134
---
1
F134
---
1
F134
ms
0.1
F001
---
1
F001
---
1
F134
---
1
F134
---
1
F134
---
1
F134
---
1
F126
---
1
F300
---
1
F300
---
1
F102
---
1
F001
ms
0.1
F001
---
1
F001
---
1
F001
kohms
0.001
F001
ms
0.1
F001
---
1
F001
---
1
F001
---
1
F102
kohms
0.001
F001
---
1
F601
ms
10
F001
ms
10
F001
---
1
F001
DEFAULT
0 (Disabled)
1
1
30
0
0 (Disabled)
0
0 (English)
10
300
0 (25%)
0 (Disabled)
30
20
10
2 (n/a)
0
0
2 (n/a)
1 (OK)
2 (n/a)
0
0
2 (n/a)
2 (n/a)
1 (OK)
2 (n/a)
0 (No)
0
0
0 (Disabled)
0
15
1
2
100
15
0
0
0 (Disabled)
100
0 (RS485)
0
0
254
GE Multilin

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents