Serial Screen
Type

Reset Timer

The status table also provides a means for establishing the Reset Timer
threshold. This read/write field is used to establish the contiguous number of
seconds that an alarm parameter must be clear before the alarm is reset.
Applicable values range from 000 through 900. A value of "000" means the
alarm will never be reset. The default value is 30.
The Network screen provides the following user-activated buttons:
Button
Function
Submit
Sets any values that have been changed.
Clear Alarms
Resets the alarm conditions and counts to zero.
Network Services
Displays the Services screen for the Network interface.
Refresh
Refreshes data on the current page.
The Serial screen (Figure 3.5) lets you view and make configuration changes
to the unit's Serial interface as described below. To make changes to any
Serial port parameter, simply set the parameter to the desired selection and
press the "Submit" button.
Figure 3.5
Serial Screen
Selects the type of interface (based on its electrical signal characteristics) used
by the equipment connected to the Serial port.
Values: V.35, RS-232, EIA-530
Default: V.35
NOTICE:
V.35 requires the use of an optional cable. Refer to "Optional
Equipment" on page A-4 for ordering information.
W e b S e r v e r I n t e r f a c e
3-7