Bert Table - Verilink WANsuite 5330 Reference Manual

Table of Contents

Advertisement

Setting
BERT Pattern
Test Duration
Pattern Sync
Elapsed Time
Bit Errors
Errored Seconds
3-42
W A N s u i t e 5 3 3 0
Figure 3.31
Test Details Screen

BERT Table

The BERT table lets you set the test parameters described below.
Displays the bandwidth on which you wish to perform the BERT. The
available values for this parameter depend on which interface is selected, so
for the network interface would be Net.
Specifies the pattern to be transmitted during a test for the selected port.
Values: Marks, QRSS, 511, 2047, ITU 2
Default: 511
15
NOTICE:
The 2
pattern is the ITU (European) version, not the ANSI version.
Specifies the length of time for which the test should run for the selected port.
Values: 15 minutes, 30 minutes, 1 hour, 24 hour, Continuous
Default: 15 minutes
The BERT Table screen also displays the following read-only parameters:
Displays the state of pattern sync during a test. If no test is in progress, "No
Test" is displayed. If a test is active, but the receiver is not in pattern sync,
"No Sync" is displayed. If the receiver is in pattern sync, "In Sync" is
displayed.
Displays the time elapsed since a timed test began or, if completed, the total
test time.
Displays the total number of bit errors detected since the test began or since
error statistics were cleared.
Displays the number of asynchronous errored seconds detected since the test
began or since error statistics were last cleared.