ABB RER620 Technical Manual page 292

Advanced recloser protection and control
Hide thumbs Also See for RER620:
Table of Contents

Advertisement

Section 5
Control functions
Input
TripIn_A
Example
TripIn_B
TripIn_C
TripIn_3P
51P/
TripIn_N
51N
PickupIn_A
PickupIn_B
PickupIn_C
TripIn_A
TripIn_B
TripIn_C
TripIn_3P
50-1P/
TripIn_N
50-1N
PickupIn_A
PickupIn_B
PickupIn_C
TripIn_A
TripIn_B
TripIn_C
TripIn_3P
50-2P/
TripIn_N
50-2N
PickupIn_A
PickupIn_B
PickupIn_C
TripIn_A
TripIn_B
TripIn_C
TripIn_3P
50-3P/
TripIn_N
50-3N
PickupIn_A
PickupIn_B
PickupIn_C
TripIn_A
TripIn_B
TripIn_C
TripIn_3P
67P/
TripIn_N
67N
PickupIn_A
PickupIn_B
PickupIn_C
TripIn_A
TripIn_B
TripIn_C
TripIn_3P
TripIn_N
Spare
PickupIn_A
PickupIn_B
PickupIn_C
CbPos_a
CSWI
CbPos-b
CbPos_c
Settings:
SinglePhaseMode = APAT, OPUP or OOAP
Order Code
RecloserType = 1P or 3P
286
SDAIGGIO1
Active_A
Active_B
Active_C
Active_3P
TripOut
SDAIGGIO2
Active_A
Active_B
Active_C
Active_3P
TripOut
SDAIGGIO3
Active_A
Active_B
Active_C
Active_3P
TripOut
SDAIGGIO4
Active_A
Active_B
Active_C
Active_3P
TripOut
SDAIGGIO5
Active_A
Active_B
Active_C
Active_3P
TripOut
SDAIGGIO6
Active_A
Active_B
Active_C
Active_3P
TripOut
Figure 142:
Logical overview diagram with internal connections in overall
Autoreclosing functionality
The logical diagram showing internal connections between SDAIGGIO input blocks,
SDARREC Core block and SDAOGGIO output block is shown in Figure 142.
The 3 sections of overall Autorecloser functionality explained below.
Active1_A
Active1_B
Active1_A
Active1_C
Active2_A
Active1_3P
Active3_A
A
Active_PhA
Active4_A
Active2_A
Active5_A
Active2_B
Active6_A
Active2_C
Active2_3P
Active1_B
Active2_B
Active3_A
Active3_B
B
Active_PhB
Active4_B
Active3_B
Active5_B
Active3_C
Active6_B
Active3_3P
Active1_C
Active4_A
Active2_C
Active4_B
Active3_C
C
Active4_C
Active_PhC
Active4_C
Active4_3P
Active5_C
Active6_C
Active5_A
Active5_B
Active1_3P
Active5_C
Active2_3P
Active5_3P
Active3_3P
3P
Active_Ph3P
Active4_3P
Active6_A
Active5_3P
Active6_B
Active6_3P
Active6_C
Active6_3P
SDAOGGIO
Active_PhA
Active_PhB
Active_PhC
Active_Ph3P
CbPos_a
CbPos_b
CbPos_c
CbPos_3P
Reclose_in
Open_in
Lockout_in
inProgress_in
timeUnsuccessfulCB = from DARREC
Three phase lockout override = Disabled or Enabled
RecloserType = 1P or 3P
1MAC309294-MB F
SDARREC
BLOCK
RESET
RS_COUNT
REC_T_STD
REC_T_ELA
InIni1
InIni2
Op (Reclose)
InIni3
OpOpn (Open)
InIni4
LO (Lockout)
InIni5
inProgress
Inini6
CB_Pos
DARREC Settings
OpenCb_A
CloseCb_A
Locked_A
OpenCb_B
CloseCb_B
Locked_B
Output
OpenCb_C
CloseCb_C
Locked_C
OpenCb_3P
CloseCb_3P
Locked_3P
Ar_CbPos
Settings:
Order Code
Output
RER620
Technical Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents