Floor load from the dish-washing machine
The floor load per foot (with a loaded surface of D=30 mm per foot) is: appr. 220 kg
7.5

Instructions for the disposal of the packaging material

 The four-sided wooden frame consists of untreated, raw pine / spruce. Special
country-specific import regulations may also stipulate the use of wood which has been
treated against pests.
 The plastic sheeting (PE sheeting) may be recycled.
 The cardboard packaging material used to protect the edges can also be recycled.
 The steel tensioning strap made of strip steel may be recycled with the steel scrap.
 The plastic tensioning strap of plastic (PP) can be recycled.
7.6
Connection to the electricity supply
Work on the electrical part of the machine may only be undertaken by specialist
personnel. The wiring diagram is located in the switch cabinet. This wiring diagram is part
of the machine and therefore must not be removed.
The manufacturer's plate with the connected electrical loads is located inside the switch
cabinet.
General Electrical Regulations must be observed when connecting the machine to the
power supply.
Only for USA / Canada:
The dishwasher must be / is installed in accordance with local codes, or in the absence
of local codes, installed in accordance with the applicable requirements in the National
Electrical Code, NFPA 70, Canadian Electrical Code (CEC), Part 1, CSA C22.1, and
Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations,
NFPA 96.
Important:
The fuses on site must be selected to suit the local conditions and the appliance's
nominal current in such a way that back-up protection is guaranteed (Germany:
VDE 0100).
The mains supply cables must be provided with fuses in accordance with
regulations and must have a main switch (accessible on site or inside the appliance
for operating personnel).
If the neutral conductor (N) is not grounded, a 4 phase main switch must be used.
Cables connecting to the main power supply must be oil-resistant and sheathed
and must not be lighter than an H 07 RN-F cable.
The potential equalisation connection must be carried out in accordance with the
requirements of the local electricity supply company and all applicable local
regulations (in Germany VDE 0100 Part 540 must be observed).
Connect
the machines to the on-site potential equalization. The machine-side
connection is located very close to the machine's central switch cabinet / unit sheet
on the undercarriage in the form of a screw and is marked accordingly.
Where VDE 0160 / EN 50178 applies, there is a requirement that in areas of electrical
equipment where line-side residual current protective circuit breakers (FI) are
planned or installed, an FI type B device sensitive to all types of currents must be
installed before the FI type A.
For the supply connection use a 5-pole terminal strip (L1, L2, L3, N, PE).
The electrical connection data, voltage, type of current, output can be seen on the
manufacturers' plates on the machine.
Please check the voltage.
All electrical connections must be made inside the electrical switch cabinet by means of
marked screwed cable glands as in the circuit diagram and connected to the terminals
and the fuses provided.
W e reserv e the right to change execution and construction!
19/52