Installation And Assembly - Meiko M-iQ Operating Instructions Manual

Belt conveyor - dishwashing machine
Table of Contents

Advertisement

Operating instructions dish-washing machine model M-iQ
CAUTION!
Datei:BA_B-M-iQ_9675717_EN_2010-01.docx
MEIKO Maschinenbau GmbH & Co. KG, Englerstraße 3, D-77652 Offenburg, Tel.: +49/781/203-0, Fax: +49/781/203-1121
7.3

Installation and assembly

MEIKO has prepared an assembly diagram showing the machine dimensions and the
connected loads in detail.
Assembly is completed by reference to the assembly diagram and, in general, by
following the instructions of a trained MEIKO engineer.The installation must only be
connected by suitably qualified personnel.
We accept no liability for connections carried out by unqualified personnel.
After unpacking, position the appliance as indicated in the assembly diagram and as the
dimensions allow.
The appliance must be level and straight when erected.
If the machine is delivered divided in a number of parts, the joints must be thoroughly
treated with P819 activator (fig. 1). Seal the cut-off points with sealing tape (fig. 2). Seal all
joints of the sealing tape with silicon (Sista F 108 (fig. 3) or M 509 (fig. 4); Sikaflex 260 (fig.
5) in paint shops. Cut clear all drill holes underneath with a punch.
Seal cut-off points on one side with sealing
tape (always flush to the machine interior).
Cut off excess sealing tape.
Sealing a gap between two tanks:
Seal cut-off points on one side with a sealing tape (always flush to the machine interior).
Attach the first strip of sealing tape on the door side flush on the interior. Adhere the
second strip of sealing tape next to the first and cut flush.
Sealing a gap between the tank and neutral element:
Seal cut-off points on one side with a sealing tape (always flush to the machine interior).
Attach only one strip of sealing tape to the door side flush on the interior.
Then assemble, align and screw together the machine parts.
For screwing parts we recommend:
1 x Hexagon head cap screw M5 x 12
2 x Front disc
1 x Cap nut selflocking M5
(Fig. 1)
Sista P819 activator
MEIKO order no.:
order Nr. 9 503 233
W e reserv e the right to change execution and construction!
Seal all joints of the
sealing tape with
(Fig. 2)
Sealing strip
Sista F 108
9 668 373
Special Silicon adhesive
order no.: 0 870 001
Cut clear all drill
holes with a punch.
silicon.
Sista M 509 Special
(4)
Silicon adhesive,
Order no.9518385
Fig. 3
Sikaflex–260 strong adhesive
order no.: 0 870 030
order no.
Fig. 5