Parameters - Eliwell TelevisGo User Manual

Family of devices used to monitor, control and manage commercial refrigeration installations from a distance
Table of Contents

Advertisement

7.3.1 PARAMETERS

IMPORTANT: A parameter map is not available for all devices.
This function is not available for these devices.
To Read and Write the parameters of individual devices, go to:
Functions
The following screen opens:
Filter devices
Description
A
The following controls will be visible:
(A) Device filters, to filter by device description.
(B) View list of network devices grouped by interface.
(E) Expand/hide devices in an interface.
Devices can be selected using the relative radio button to the left of the address (C).
Only one device can be selected at a time.
The following buttons are presented at the top (F):
Expand all: to view the devices of all interfaces in the list.
Collapse All: to hide the devices of all interfaces in the list.
Cancel Filters: to restore the display of all devices and cancel device filters.
Click
to go to the next page. This screen shows all parameters of the selected device:
Time interval
F
A
Address: 0.02:00
Description: ID 974LX
Name:
Parameter filters
Group
All
Label
B
Description
Checked rows
Unchecked rows
Empty values
C
Filled values
Valid data
Invalid or missing values
Legend
Read/write
D
Read only
Load parameter map
E
Browse...
TelevisGo
Parameters
Expand all
Interface
ID
LAN Adapter
0
Address
B
02:00
02:01
C
Compact
999
Address
Select all
Deselect all
Copy from default
Label
Description
SEt
Regulation set point
diF
Tripping differential
HSE
Maximum value settable for set point
H
LSE
Minimum value settable for set point
OSP
Offset on set point
Cit
Minimum enabling time for compressor output
CAt
Maximum enabling time for compressor output
dOd
Loads shutdown enabling after door micro enabling
dAd
Enabling delay of digital inputs
Ont
ON time for compressor output with faulty regulation probe
OFt
OFF time for compressor output with faulty regulation probe
dOn
Compressor output enabling delay from request
dOF
Compressor output enabling delay from shutdown
dbi
Delay between two consecutive starts of the compressor output
OdO
Delay output enabling from Power On
dty
Type of defrost
dit
Interval between defrosts
dt1
Unit of measurement for defrost intervals
dt2
Unit of measurement for defrost duration
dCt
Defrost interval count mode
dOH
Defrost cycle enabling delay from request
D
Collapse all
Cancel filters
Address
Protocol
192.168.0.1
Micronet
N/A
Page last update on: 7.39.34
Copy from device
Read
Write
Save parameter map
UM
°C/°F
°C/°F
°C/°F
°C/°F
°C/°F
min
min
flag
min
min
min
s
min
min
min
flag
h/min/s
flag
flag
flag
min
Fieldbus
LanAdapter
Name (short)
Description
ID 974LX
0.02:00 ID 974LX
IC 974LX
0.02:01 ID 974LX
BusAdapter
Name (short)
Description
Load parameter map
Cancel filters
Min
Max
Default
Device
Input
LSE()
HSE()
-2.4
0.1
30.0
0.3
LSE()
302.0
-1.0
-58.0
HSE()
-2.4
-30.0
30.0
0.0
0
250
0
0
250
0
0
1
0
0
255
0
0
250
10
0
250
3
0
250
0
0
250
3
0
250
0
0
250
0
0
2
0
0
250
8
0
2
0
0
2
1
0
2
1
0
59
59
E
G
Print
I
Page 55/68