User: Operation; Alarm Display; Data Display; Real Time Data - Eliwell TelevisGo User Manual

Family of devices used to monitor, control and manage commercial refrigeration installations from a distance
Table of Contents

Advertisement

7. USER: OPERATION

Using the simple, intuitive interfaces, users can view data and/or alarms in real time, explore the data archive/alarm log, view
graphs and download all data viewed.
IMPORTANT: Network alarms and real-time data are only detected when TelevisGo data logging is running!

7.1 ALARM DISPLAY

All switches to alarm condition are recorded, except for when a delay time has been set up and the alarm itself did not persist for
longer than the time set in the delay.

7.2 DATA DISPLAY

There are two ways of viewing data recorded by network devices:
Real-time data
Historical data

7.2.1 REAL TIME DATA

To view real time data, go to:
Data
The following screen opens:
Arrangement
A
1 Column
Selection filters
Description
B
Apply
Select the resources
Resource
Analog
input
C
Digital
input
States
Legend
Compressor
Defrost
D
Fan
Port
This page is similar to the Televis one, and can only be accessed when data logging is running.
You can filter by:
Controller name (B)
Type of resource (C)
Devices are grouped by interface; users can distribute the list over 1, 2, 3, 4 or 5 columns using the drop-down menu (A).
TelevisGo
Real Time Table
LanAdapterWiFi (192.168.0.1)
0.02:00 ID 974LX
Analog input 1
Door
Alarm output
Compressor 1
Defrost 1
Evaporator fans 1
0.03:00 ID 974LX
Analog input 1
Door
Alarm output
Compressor 1
Defrost 1
Evaporator fans 1
Compact
- 1 Device
999.14:14 TelevisCompact
Modem signal strength
Relay 1
Relay 2
- 2 Devices
E
-3276,8 °C
Closed
Active
Inactive
Active
Inactive
-3276,8 °C
Closed
Active
Inactive
Active
Inactive
* * %
Inactive
Inactive
Page 45/68