Chapter 4 Connection and Settings
4.4 Connecting to the Server UPS Unit
3
When two or more AC sensor units are connected, connect the AC sensor units with the AC
sensor port connection cables.
3-1
Connect the AC sensor port connection cable to the other port on the branch connector.
AC sensor port connection cable
3-2
Connect the connector at the other end of the AC sensor port connection cable to another AC sensor
unit.
AC sensor port connection cable
Up to 14 AC sensor units can be connected.
Do not attach a termination resistor to the branch connector on the AC sensor unit. Doing so
makes operations unstable.
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)