Chapter 6 Operation and Maintenance
6.3 Troubleshooting
WARNING
The power synchronized unit does not turn on
Check the following points:
If you still have trouble, leave the power synchronized unit as it is and contact your sales representative or
maintenance engineer.
The power cord (for AC power input) is not correctly connected to the AC IN port.
The CHECK LED is left on.
The power synchronized unit must be replaced. Contact your sales representative or maintenance
engineer.
The ETERNUS DX/AF does not turn off with the power synchronized server
Check the following points:
If you still have trouble, leave the power synchronized unit as it is and contact your sales representative or
maintenance engineer.
The power synchronized unit is not turned on.
A CM or an SVC is in a failed state.
The POWER LED and POWER SENSOR LED are on.
-
Check the status for the SENSOR#0 port and SENSOR#1 port on the power synchronized unit and the
status for the AC output of the server UPS unit to which the AC sensor unit is connected.
The AC output of all the connected server UPS units needs to be off to turn off the ETERNUS DX/AF.
-
Check the status for the SENSOR#0 port and SENSOR#1 port on the power synchronized unit and the
status of the cable connection for the AC sensor unit.
-
When the power synchronized units are cascaded, check the connection status of the cascade cables.
The POWER LED is on and the POWER CONTROL LED is blinking.
-
Check that the ETERNUS DX/AF is not being turned off.
It may take time for the ETERNUS DX/AF to turn off. Wait for a while and check that the status of the
LEDs does not change.
-
When different power synchronized units are connected to CM#0 and CM#1, or SCV#0 and SVC#1 on the
ETERNUS DX/AF, the ETERNUS DX/AF must be turned off by both power synchronized units.
-
Check that power synchronization with the power synchronized unit is correctly set for the ETERNUS DX/
AF.
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Unplug
If the power synchronized unit overheats, gives off smoke or an unusual odor,
makes an unusual sound, or shakes abnormally, or is likely to be damaged by
a power abnormality, immediately remove the power cords.
After waiting a while, check that the unusual phenomena has disappeared,
and then contact your sales representative or maintenance engineer.
74
Copyright 2017 FUJITSU LIMITED
P3AM-8012-10ENZ0