Chapter 1 Overview

1.5 System Configuration

1.5
System Configuration
System configuration examples when the power synchronized unit is used are shown below.
The server UPS unit must have a function in the management software (PowerChute plus, etc.) that controls
the AC power output according to when the server powers on and off.
Power synchronization with two server UPS units
The following configuration is an example of power synchronization with two server UPS units.
One power synchronized unit can connect up to two server UPS units and four ETERNUS DX/AF storage
systems.

Figure 1.5 System configuration example (power synchronization with two server UPS units)

UPS unit for
Server#0
Provided cables are indicated by solid lines.
Optional cables that can be added are indicated by dotted lines.
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide (Power Synchronized Unit)
Server#0
Server#1
SENSOR#0
SENSOR#1
Power synchronized unit#0
#0
#1
#2
#3
PWC#0
ETERNUS DX/AF
PWC
Power cord (for AC sensor)
Power cord (for AC power input)
RS232C cable
Copyright 2017 FUJITSU LIMITED