Using the Data Logging Utility Software to recover data
ATTENTION
!
The Data Logging utility is the only supported method for
retrieving data, that has been stored in the processor.
1. Install the DLOG utility (found at
micrologix/)
2. Execute DLCA1764.EXE
3. Configure Port, Baud Rate, and DF1 Node as shown below.
4. Click "Connect".
FYI - By default the MicroLogix 1400 communications are
configured for 19200 baud If using defaults select 19200 above,
otherwise select the baud rate configured in the MicroLogix Channel
Configuration Screen.
If a correct configuration has been selected the utility software will
indicate that it has connected to the processor as shown below.
If any other software package, such as RSLINX has control of the
computers communication port or if the wrong COM port is selected or a
processor other then the MicroLogix 1400 is connected to the computer you
will not be able to continue.
http://www.ab.com/plclogic/