Download Print this page
Allen-Bradley 1305-RFB-5-A User Manual
Allen-Bradley 1305-RFB-5-A User Manual

Allen-Bradley 1305-RFB-5-A User Manual

The input rfi filter units are designed to be used with the following adjustable frequency ac drives: 1305; 1336 plus; 1336 plus ii; 1336 force; 1336 impact

Advertisement

Quick Links

User
Input RFI Filters
Manual

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1305-RFB-5-A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Allen-Bradley 1305-RFB-5-A

  • Page 1 User Input RFI Filters Manual...
  • Page 3 This publication provides the steps needed to install the filter. Important: Declarations of Conformity to the European Union Directives are available for Allen-Bradley AC Drive Products. Please contact your Allen-Bradley Sales Representative.
  • Page 4 Braided Shield 190.0 (7.48) 40.0 (1.57) 53.2 (2.09) 250.0 (9.84) 5.3 (0.21) 38.1 (1.50) All Dimensions in Millimeters and (Inches) Catalog Weight Number kg (lbs.) 0.85 1305-RFB-5-A 122.0 235.0 40.5 90.0 215.0 180.0 110.0 195.0 (4.80) (9.25) (1.59) (3.54) (8.46) (7.09) (4.33)
  • Page 5 Input RFI Filters ATTENTION: To prevent electrical shock, disconnect the power source before installing or servicing. 1. Mount the filter to the panel. Refer to the Dimension drawing shown on the previous page. 2. Remove and discard the plastic conduit panel of the 1305. Replace with the supplied metal conduit panel.
  • Page 6 Input RFI Filters ATTENTION: To guard against possible equipment damage, RFI filters can only be used with AC supplies that are nominally balanced with respect to ground. In some installations, three-phase supplies are occasionally connected in a 3-wire configuration with one phase grounded (Grounded Delta).
  • Page 7 Input RFI Filters 1336 PLUS, FORCE and PLUS Use the cross reference below to verify that the correct filter has been selected for your CE compatible drive. In addition, ensure that the IMPACT Filter Installation drive was ordered with the “-AE” enclosure option or the EMC Enclosure Kit (1336x-AEx) has been properly installed.
  • Page 8 Input RFI Filters Filter Dimensions TB Cover = 50.0 (1.97) x 41.0 (1.61) x 66.0 (2.60) 6.5 (0.26) Braided Shield 100.0 (3.94) 10.0 (0.39) 10.0 (0.39) 1.0 (0.04) All Dimensions in Millimeters and (Inches) Catalog Weight Number kg (lbs.) 1336-RFB-7-AA 50.0 255.0 126.0...
  • Page 9 Input RFI Filters Filter Dimensions (continued) Conduit Fitting Catalog Weight Number kg (lbs.) 1336-RFB-30-A4 260.1 413.7 58.0 230.1 320.0 15.0 70.0 15.0 (10.24) (16.29) (2.28) (9.06) (12.60) (0.59) (2.76) (0.59) (10.8) 1336-RFB-27-B 276.6 540.0 58.0 212.6 461.0 10.9 68.1 32.0 (10.89) (21.26) (2.28)
  • Page 10 Input RFI Filters Filter Dimensions (continued) 122.0 (4.08) 122.0 (4.08) 5.0 (0.20) Dia. Ground Stud Catalog Weight Number kg (lbs.) 1336-RFB-475-G 300.0 794.0 160.0 275.0 200.0 70.0 12.5 740.0 29.0 (11.81) (31.26) (6.30) (10.83) (7.87) (2.76) (0.49) (29.13) (63.9) 1336-RFB-590-G 1336-RFB-670-G...
  • Page 11 Input RFI Filters ATTENTION: To prevent electrical shock, disconnect the power source before installing or servicing. 1. Perform the appropriate step below (A, B, C, D or E) to mount the filter and drive. A. 1336-RFB-7-AA, 16-AA, 30-A Filters Mount the filter and drive to the panel. See the Dimension & Mounting diagrams provided in this document.
  • Page 12 Input RFI Filters 2. The RFI filter must be connected between the incoming AC supply line and the drive input terminals. Important: The filter may cause ground leakage currents. Therefore a solid ground connection must be provided as shown below. Remove the filter access panel (or terminal block cover) to expose the input terminal block.
  • Page 13: Filter Mounting

    Input RFI Filters Filter Mounting Series B Filters can be mounted using either method Important: A positive electrical bond must be maintained between drive and filter at all 4 corners. Star washers can be eliminated if a positive electrical bond is Three-Phase Input assured.
  • Page 14 Input RFI Filters Filter Mounting (continued) Important: Drive and filter must be mounted to a common back plane with a positive electrical bond. Spacing is determined by Conduit Box. Three-Phase Three-Phase Input Input Access Panel and Input Terminal Block Lower Access Panel To Motor To Motor Conduit Box...
  • Page 15 831.0 (32.72) Important: This information represents the method used to mount 1336-RFB-475, 590 & 670 filters in an Allen-Bradley supplied EMC enclosure. User supplied EMC enclosures must Typical Drive Placement follow all of the guidelines shown. Illustrations are only intended to identify structural mounting points and hardware shapes.
  • Page 16 Input RFI Filters 1336 PLUS, FORCE & IMPACT Knockout Definitions PLUS Dimensions are in Millimeters and (Inches) Frames A1 through A4 Frames B and C Control I/O Motor Output Filter Input Motor Output Filter Input Control I/O SCANport SCANport 22.2 (0.88) - 1 Plc. 28.6/34.9 (1.13/1.38) - 3 Plcs.
  • Page 18 Publication RF-101ML-EN – December, 1999 P/N 74103-446-01 (06) Supersedes July, 1999 Copyright 1999 Rockwell International Corporation. All rights reserved. Printed in USA.