Multi-function output terminal operation (d01 and d08)

Setting Freq.
Detective Range
± 2Hz
Desired Freq.
Setting
P47
Pre-set Freq.
attained indication
P45/46
Desired Freq.
Attained Setting
P45/46
Pr.48 Output Frequency Offset (can be programmed while the dirve is running)
Factory Setting d0.00
Units 0.1 Hz
Parameter value d0.0 - d350.0 Hz
Pr.49 Process Signal Bias (can be programmed while the dirve is running)
Factory Setting d00
Units none
Parameter value d00 (minimum output frequency corresponds to 0 V, 4 mA)
d01 (minmum output frequency corresponds to potential bias)

Pr.50 Process Signal Gain

Factory Setting d100
Units 1%
Parameter value d01 - d200%
Pr.51 Process Signal Reverse Motion
Factory Setting d00
Units none
Parameter value d00 (forward motion only)
d01 (reverse motion enabled)
VLT
Detective Range
± 4Hz
OFF
ON
ON
43
®
MICRO
Inefficient Range
– 2Hz
OFF