Chapter 5 Summary Of Parameters - Danfoss 176F7300 Manual

Vlt micro
Table of Contents

Advertisement

Chapter 5
Summary of Parameters
This chapter summarizes all 10 of the parameter groups. For complete descriptions of
individual parameters refer to Chapter 4.
No. Parameter
Function
Name
Explanation
00
Master Speed Master frequency
Frequency
source select
Setting
01
Operation
Operation
Command
command
Source
source select
02
Motor stop
Motor stop
method
method select
03
V/F Curve
Max output freq.
04
Setting
Max voltage freq.
05
(13 & 14)
Max output volt
06
Mid-point freq.
07
Mid-point volt
08
Min output freq.
09
Min output volt
10
Accel/Decel
Acceleration time 1 d0.1 - d600. sec
11
Time Setting
Deceleration time 1 d0.1 - d600. sec
12
Acceleration time 2 d0.1 - d600. sec
VLT
Parameter
Value
d00:Master frequency input
determined by the digital
control panel
d01:Master frequency input
determined by the analog
signal (DC 0 to +10 V)
d02:Master frequency input
determined by the analog
signal (DC 4 to 20 mA)
d00:Operating instructions
determined by the digital
control panel
d01:Operating instructions
determined by the external
terminal connections,
keypad STOP key effective
d02:Operating instructions
determined by the external
terminal connections, keypad
STOP key not effective
d00:RAMP stop
d01:Coasting to stop
d50.0 - d400. Hz
d10.0 - d400. Hz
d2.0 - d255.0 V
d0.1 - d400. Hz
d002.0 - d255. V
d0.1 - d20.0 Hz
d2.0 - d50.0 V
62
®
MICRO
Factory
Setting
d00
d00
d00
d60.0
d60.0
d220.
d1.50
d12.0
d1.50
d12.0
d10.0
d10.0
d10.0

Hide quick links: