Pr.80 Manufacturer Model Information

Factory Setting d##
Units None
Settings
d00 220V 3-Phase/1-Phase 0.5Hp
d01 400V 3-Phase/1-Phase 0.5Hp
d02 220V 3-Phase/1-Phase 1.0Hp
d03 400V 3-Phase/1-Phase 1.0Hp
d04 220V 3-Phase/1-Phase 2.0Hp
d05 220V 3-Phase/1-Phase 2.0Hp
d06 200V 3-Phase/1-Phase 3.0Hp
d07 200V 3-Phase/1-Phase 3.0Hp
This parameter contains information on the drive: model number, firmware version, etc.
(The parameter is read only).

Pr.81 ~ Pr.87 PLC Program Step Time Intervals

Factory Setting d0.0
Units 10 Sec
Settings d0.0 - d650
Each of the parameters: 81 to 87 control the time intervals for each Multi-speed Step
defined by Pr.17 to Pr.23.
Pr.88 ~ Pr.94 Serial Communication (See Appendix D in this manual.)

Pr.95 Auto Energy-saving

Factory Setting d00
Units None
Settings
d00 Without energy-saving operation
d01 With energy-saving operation
While enabling auto energy-saving, the AC motor drive operates at full power during
acceleration/deceleration, and provides the motor optimum voltage calculated
automatically based on the load power when operating at fixed rotation speed. This
function is not suitable for frequent load variation or load whose operation voltage is
close to its rated load.
output voltage
100%
70%

Output characteristics curve of energy-saving operation

VLT
output frequency
base frequency
58
®
MICRO