5.11 Selecting control mode

 : V/F control mode selection
 Function
With VF-nC3, the V/F controls shown below can be selected.
 V/F constant
 Variable torque
 Automatic torque boost control *1
 Vector control *1
 Energy saving *1
(*1)
Parameter setting macro torque boost:  parameter can automatically set this parameter and
auto-tuning at a time. (Refer to section 5.4)
[Parameter setting]
Title
V/F control mode selection

Note:  (V/F control mode selection) is valid only for the first motor.
Changes to "V/F constant control" when switching to the second motor, regardless of the  setting.
Steps in setting are as follows
(In this example, the V/F control mode selection parameter  is set to  (Vector control).
[Setting V/F control mode selection to 3 (sensorless vector control)]
Operation panel
action
MODE
Function
0: V/F constant
1: Variable torque
2: Automatic torque boost control
3: Vector control
4: Energy-saving
LED display
Displays the output frequency. (Perform during operation stopped.)
. 
(When standard monitor display selection = [Output frequency])
The first basic parameter "" (history function) is displayed.

Rotate the setting dial to the right, and change the parameter to 

(control selection).
Parameter values can be read by pressing the center of the setting
dial (the default setting is :V/F constant).
Rotate the setting dial to the right, and change the parameter to 
(vector control).
Press the center of the setting dial to save the changed parameter.
 
 and parameter set value "" are displayed alternately.
E-17
Adjustment range
Operation
E6581595
Default setting
5
0