Toshiba TOSVERT VF-nC3 Instruction Manual page 94

Hide thumbs Also See for TOSVERT VF-nC3:
Table of Contents

Advertisement

When vector control cannot be programmed
First read the precautions about vector control in section 5.11-6).
1) If the desired torque cannot be obtained ⇒ Refer to section 6.14 selection 2
2) If auto-tuning error "" appears ⇒ Refer to section 6.14 selection 3
 (Torque boost setting macro function) and  (V/F control mode
selection)
Automatic torque boost is the parameter for setting V/F control mode selection () and auto-tuning
() together. That is why all parameters related to change automatically when  is changed.

 Displays  after resetting
Automatic torque boost +
auto-tuning
 Vector control + auto-tuning
 Energy saving + auto-tuning
4) Increasing torque manually (V/F constant control)
This is the setting of constant torque characteristics that are suited for such things as conveyors. It can also be
used to manually increase starting torque.
If V/F constant control is programmed after changing ,
Set V/F control mode selection  =  (V/F constant).
Note 1: To further increase torque, increase the torque boost amount 1.
How to set the torque boost amount 1
Note 2: V/F control selection = 1 (variable torque) is an effective setting for load such as fans and
pumps.
Automatically programmed parameters

-
Check the programmed value of .
Automatic torque boost
Vector control
Energy saving
E-9
E6581595

-
Auto-tuning
executed
(after execution: 0)
Auto-tuning
executed
(after execution: 0)
Auto-tuning
executed
(after execution: 0)
 Refer to section 5.11
 Refer to section 5.12
 Refer to section 5.11
5