Drives Reported As "Dead" When Starting System; Added Drive Reported As Defective - PRIMERGY TX300 S3 Operating Manual

Table of Contents

Advertisement

Troubleshooting and Tips
7.9
Drives Reported as "Dead" When Starting
System
This error message can occur when the Onboard SAS controller has RAID
functionality or the server is equipped with a PCI RAID controller.
RAID controller configuration incorrect
Ê Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.
7.10

Added Drive Reported as Defective

RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the hard disk drive continues to be shown as defective, then replace it (see
section "Installing/Removing the HDD Module" on page
TX300 S3
Operating Manual
Drives Reported as "Dead"
92).
83

Advertisement

Table of Contents
loading

Table of Contents