Drives Reported As "Dead" When Starting System; Added Drive Reported As Defective; Error Message On Screen - PRIMERGY Econel 230R S1 Operating Manual

Table of Contents

Advertisement

Troubleshooting and tips Drives reported as "dead" when starting system
7.9
Drives reported as "dead" when starting
system
This error message can occur when the onboard SAS controller has RAID func-
tionality or the server is equipped with a PCI RAID controller.
RAID controller configuration incorrect
Ê Check and correct the settings for the drives using the RAID controller utility.
Further information is provided in the manual for the RAID controller.
7.10

Added drive reported as defective

RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the drive continues to be reported as defective, then replace it (see
ling/removing the HDD module" on page 75
on page
77).
7.11

Error message on screen

The meaning of the error message is explained in the manual for the BIOS-Setup
and in the documentation for the relevant components and programs on the
PRIMERGY ServerBooks DVD.
Econel 230R S1
and
Operating manual
"Removing the HDD module"
"Instal-
69

Advertisement

Table of Contents
loading

Table of Contents