Installing/Removing The Rack Model - PRIMERGY TX300 S3 Operating Manual

Table of Contents

Advertisement

Hardware Installation
4.3

Installing/Removing the Rack Model

V
CAUTION!
Please observe the safety notes and notes on mounting into the rack
in
chapter "Important Information" on page
Several people are needed to install / remove the server in the rack.
The rack can tip over when more than one slide-in module is pulled
out.
The server may not occupy the top height unit of the rack (42 HU
Classic Rack, 38 HU/42HU PRIMECENTER Rack and/or DataCenter
Rack), as otherwise no board and/or system fan can be replaced
even with the slide-in module pulled out completely.
Rack requirements
The rack systems produced by Fujitsu Siemens Computers (PRIMECENTER
Rack; DataCenter Rack and 19-Inch (Classic) Rack) fully support the instal-
lation of PRIMERGY server systems. Installation in most current rack systems
from other manufacturers (3rd party racks) is also supported.
To accommodate the ventilation concept and ensure proper ventilation, any
unused areas in the rack must be sealed using dummy covers.
The power is supplied via the multiple socket outlets fitted in the rack.
TX300 S3
Installing/Removing the Rack Model
Operating Manual
19.
35

Advertisement

Table of Contents
loading

Table of Contents