3- -2. Code Example for Watchdog Timer
Enable watchdog timer and set the timeout interval as 30 seconds.
;------ Enter to extended function mode --------------------------------------------------------
mov
dx,
2eh
mov
al,
87h
out
dx,
al
out
dx,
al
;------ Select Logical Device 7 of watchdog timer --------------------------------------------
mov
al,
07h
out
dx,
al
inc
dx
mov
al,
07h
out
dx,
al
;------ Enable Watch dog feature --------------------------------------------
mov
al,
030h
out
dx,
al
inc
dx
mov
al,
01h
out
dx,
al
;------ Enable Watch PME--------------------------------------------
dec
dx
mov
al,
0FAh
out
dx,
al
inc
dx
in
al,
dx
and
al,
51h
out
dx,
al
;------ Set second as counting unit --------------------------------------------------------------
dec
dx
mov
al,
0f5h
out
dx,
al
inc
dx