Protech Systems PA-6822 User Manual page 113

Table of Contents

Advertisement

Defines the download bit image of the number of dots specified by X and Y.
X specifies the number of bytes in the horizontal direction.
Y specifies the number of bytes in the vertical direction.
Horizontal direction dot count is X x 8 dots; Vertical direction dot count is Y
x 8 dots
d indicates the bit-image data. Bits that correspond to the dots to print are 1,
and the bits that correspond to the dots that are not printed are 0.
[Description]
GS ( A pL pH n m
[Name]
Execute test print.
ASCII
[Format]
Hex.
Decimal 29 40 65 pL pH n m
{pL+ (pH×256) } = 2 (pL = 2,pH = 0)
[Range]
0 ≤ n ≤ 2 , 48 ≤ n ≤ 50
2 ≤ m ≤ 3 , 50 ≤ m ≤ 51
Executes the specified test print.
The following command is ignored in page mode.
Specifies the parameter count following pL and pH in (pL + (pH x 256)) bytes.
n specifies the paper to be tested.
[Description]
m specifies a test pattern..
PA-6822 Series User Manual
GS (
A pL pH n m
1D 28 41 pL pH n m
n
Paper Type
0 , 48
Basic sheet (paper roll)
1 , 49
Paper Roll
2 , 50
m
Type of Test Print
2 , 50
Printer Status (Self Print)
3 , 51
Rolling Pattern Print
Chapter 3 Software