No.
Description
10207
>BLOCK Uphph<(<) Undervolt
(phase-phase) (>Uphph<(<)
BLK)
10208
>BLOCK U1<(<) Undervolt (posi-
tive seq.) (>U1<(<) BLK)
10215
Uph-e>(>) Overvolt. is switched
OFF (Uph-e>(>) OFF)
10216
Uph-e>(>) Overvolt. is BLOCKED
(Uph-e>(>) BLK)
10217
Uph-ph>(>) Overvolt. is switched
OFF (Uph-ph>(>) OFF)
10218
Uph-ph>(>) Overvolt. is
BLOCKED (Uph-ph>(>) BLK)
10219
3U0>(>) Overvolt. is switched
OFF (3U0>(>) OFF)
10220
3U0>(>) Overvolt. is BLOCKED
(3U0>(>) BLK)
10221
U1>(>) Overvolt. is switched OFF
(U1>(>) OFF)
10222
U1>(>) Overvolt. is BLOCKED
(U1>(>) BLK)
10223
U2>(>) Overvolt. is switched OFF
(U2>(>) OFF)
10224
U2>(>) Overvolt. is BLOCKED
(U2>(>) BLK)
10225
Uph-e<(<) Undervolt. is switched
OFF (Uph-e<(<) OFF)
10226
Uph-e<(<) Undervolt. is
BLOCKED (Uph-e<(<) BLK)
10227
Uph-ph<(<) Undervolt. is
switched OFF (Uph-ph<(<) OFF)
10228
Uphph<(<) Undervolt. is
BLOCKED (Uph-ph<(<) BLK)
10229
U1<(<) Undervolt. is switched
OFF (U1<(<) OFF)
10230
U1<(<) Undervolt. is BLOCKED
(U1<(<) BLK)
10231
Over-/Under-Voltage protection is
ACTIVE (U</> ACTIVE)
10240
Uph-e> Pickup (Uph-e> Pickup)
10241
Uph-e>> Pickup (Uph-e>>
Pickup)
10242
Uph-e>(>) Pickup L1 (Uph-e>(>)
PU L1)
10243
Uph-e>(>) Pickup L2 (Uph-e>(>)
PU L2)
10244
Uph-e>(>) Pickup L3 (Uph-e>(>)
PU L3)
10245
Uph-e> TimeOut (Uph-e> Time-
Out)
10246
Uph-e>> TimeOut (Uph-e>> Tim-
eOut)
10247
Uph-e>(>) TRIP command (Uph-
e>(>) TRIP)
10248
Uph-e> Pickup L1 (Uph-e> PU
L1)
SIPROTEC, 7SD5, Manual
C53000-G1176-C169-5, Release date 02.2011
Function
Type
of In-
for-
matio
n
Voltage Prot.
SP
*
Voltage Prot.
SP
*
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
on
off
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Voltage Prot.
OUT
*
Log Buffers
Configurable in Matrix
*
*
LED BI
*
*
LED BI
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
*
*
LED
on off
*
LED
on off
*
LED
on off
*
LED
on off
*
LED
on off
*
LED
*
*
LED
*
*
LED
on
*
LED
*
*
LED
Appendix
A.8 Information List
IEC 60870-5-103
BO
BO
BO
73
15
1
Yes
BO
73
16
1
Yes
BO
73
17
1
Yes
BO
73
18
1
Yes
BO
73
19
1
Yes
BO
73
20
1
Yes
BO
73
21
1
Yes
BO
73
22
1
Yes
BO
73
23
1
Yes
BO
73
24
1
Yes
BO
73
25
1
Yes
BO
73
26
1
Yes
BO
73
27
1
Yes
BO
73
28
1
Yes
BO
73
29
1
Yes
BO
73
30
1
Yes
BO
73
31
1
Yes
BO
73
40
2
Yes
BO
73
41
2
Yes
BO
73
42
2
Yes
BO
73
43
2
Yes
BO
73
44
2
Yes
BO
BO
BO
73
47
2
Yes
BO
73
133
2
Yes
741