Siemens SIPROTEC Manual page 724

Line differential protection with distance protection
Hide thumbs Also See for SIPROTEC:
Table of Contents

Advertisement

Appendix
A.8 Information List
No.
Description
3176
Diff: Fault detection L1 (only) (Diff
Flt. 1p.L1)
3177
Diff: Fault detection L1E (Diff Flt.
L1E)
3178
Diff: Fault detection L2 (only) (Diff
Flt. 1p.L2)
3179
Diff: Fault detection L2E (Diff Flt.
L2E)
3180
Diff: Fault detection L12 (Diff Flt.
L12)
3181
Diff: Fault detection L12E (Diff Flt.
L12E)
3182
Diff: Fault detection L3 (only) (Diff
Flt. 1p.L3)
3183
Diff: Fault detection L3E (Diff Flt.
L3E)
3184
Diff: Fault detection L31 (Diff Flt.
L31)
3185
Diff: Fault detection L31E (Diff Flt.
L31E)
3186
Diff: Fault detection L23 (Diff Flt.
L23)
3187
Diff: Fault detection L23E (Diff Flt.
L23E)
3188
Diff: Fault detection L123 (Diff Flt.
L123)
3189
Diff: Fault detection L123E (Diff
Flt. L123E)
3190
Diff: Set Teststate of Diff. protec-
tion (Test Diff.)
3191
Diff: Set Commissioning state of
Diff. (Comm. Diff)
3192
Diff: Remote relay in Teststate
(TestDiff.remote)
3193
Diff: Commissioning state is
active (Comm.Diff act.)
3197
Diff: >Set Teststate of Diff. protec-
tion (>Test Diff. ON)
3198
Diff: >Reset Teststate of Diff.
protec. (>Test Diff. OFF)
3199
Diff: Teststate of Diff. prot.
ON/OFF (Test Diff.ONoff)
3200
Diff: Teststate ON/OFF via BI
(TestDiffONoffBI)
3215
Incompatible Firmware Versions
(Wrong Firmware)
3217
Prot Int 1: Own Datas received
(PI1 Data reflec)
3218
Prot Int 2: Own Datas received
(PI2 Data reflec)
3227
>Prot Int 1: Transmitter is
switched off (>PI1 light off)
3228
>Prot Int 2: Transmitter is
switched off (>PI2 light off)
3229
Prot Int 1: Reception of faulty data
(PI1 Data fault)
724
Function
Type
of In-
for-
matio
n
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
OUT
*
Diff. Prot
IntSP
on
off
Diff. Prot
IntSP
on
off
Diff. Prot
OUT
on
off
Diff. Prot
OUT
on
off
Diff. Prot
SP
on
off
Diff. Prot
SP
on
off
Diff. Prot
IntSP
on
off
Diff. Prot
IntSP
on
off
Prot. Interface
OUT
on
Prot. Interface
OUT
on
off
Prot. Interface
OUT
on
off
Prot. Interface
SP
on
off
Prot. Interface
SP
on
off
Prot. Interface
OUT
on
off
Log Buffers
Configurable in Matrix
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
*
*
LED
FC
TN
*
*
LED
FC
TN
*
*
LED
*
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED
*
*
LED
*
LED
*
LED
*
LED
*
*
LED BI
*
*
LED BI
*
*
LED
C53000-G1176-C169-5, Release date 02.2011
IEC 60870-5-103
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
92
106
1
Yes
BO
92
107
1
Yes
BO
92
108
1
Yes
BO
92
109
1
Yes
BO
BO
BO
BO
BO
BO
BO
BO
BO
BO
93
135
1
Yes
SIPROTEC, 7SD5, Manual

Advertisement

Table of Contents
loading

Table of Contents