5. PARAMETERS
No./symbol/
Setting
name
digit
PN32
Set the 2nd octet of the IP address of the network device allowed to be connected in
decimal.
*IPOA2
When [Pr. PN31] to [Pr. PN34] are all set to "0", the function is disabled.
Operation
specification
IP address 2
When the function is enabled, the servo amplifier allows the following data 1) to 3) to
be imported only if the IP address of the master station (external device) matches
with the operation specification IP address. If they are mismatched, the data is
discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Monitoring, parameter setting, and test operation can be executed via Ethernet when
the IP addresses of a personal computer (MR Configurator2) and GOT are within the
range of the operation specification IP address. When out of the range,
communication to the servo amplifier cannot be established.
Setting range: 0 to 255
PN33
Set the 3rd octet of the IP address of the network device allowed to be connected in
decimal.
*IPOA3
When [Pr. PN31] to [Pr. PN34] are all set to "0", the function is disabled.
Operation
specification
IP address 3
When the function is enabled, the servo amplifier allows the following data 1) to 3) to
be imported only if the IP address of the master station (external device) matches
with the operation specification IP address. If they are mismatched, the data is
discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Monitoring, parameter setting, and test operation can be executed via Ethernet when
the IP addresses of a personal computer (MR Configurator2) and GOT are within the
range of the operation specification IP address. When out of the range,
communication to the servo amplifier cannot be established.
Setting range: 0 to 255
PN34
Set the 4th octet of the IP address of the network device allowed to be connected in
decimal.
*IPOA4
When [Pr. PN31] to [Pr. PN34] are all set to "0", the function is disabled.
Operation
specification
IP address 4
When the function is enabled, the servo amplifier allows the following data 1) to 3) to
be imported only if the IP address of the master station (external device) matches
with the operation specification IP address. If they are mismatched, the data is
discarded.
1) SDO Download (command: 4020h, sub command: 0002h)
2) SDO Object SubID Block Download (command: 4020h, sub command: 0006h)
3) CC-Link IE Field Network Basic request message (RWwn)
Monitoring, parameter setting, and test operation can be executed via Ethernet when
the IP addresses of a personal computer (MR Configurator2) and GOT are within the
range of the operation specification IP address. When out of the range,
communication to the servo amplifier cannot be established.
Setting range: 0 to 255
PN35
Set a value for the 3rd octet range of the IP address of the network device allowed to
be connected.
*IPOR3
The range for the IP address of the network device allowed to be connected is
Operation
between [Pr. PN33] and [Pr. PN35]. Set a value in decimal.
specification
IP address 3
Setting "256" will disable the function.
range
specification
Setting range: 0 to 256
Function
5 - 6
Initial
value
[unit]
0
0
0
256